Rice Lake Ishida IGX & IGB Series - Service Manual User Manual

Page 27

Advertising
background image

Manual No. 085-3435-07

26/45

IGB/IGX Series (Overseas Specifications) Service Manual

2.10 C9 Mode: Board Inspection (A/D Check, I/F Check)

This mode is for factory inspection, and shall not be used for maintenance.

Operation Display

1. Starting Test Mode

Press ON/OFF.
Press and hold ZERO(+) while all segments are lit.

2. Entering C9 Mode

Press ZERO(+) eight times.

Or,

press TARE(-).

3. Press SET.
Span adjusted A/D data is displayed.

4. Press SET.

A/D converter output value is displayed.

However, the lower 3 bits of 24-bit output change rapidly and
are outside of visual inspection range, so they are excluded.

5. Press ZERO(+).

Used for A/D board drift inspection.

The inspection result is displayed: OK or Err

6. Press TARE(-).

Connect the inspection jig and all I/O ports are checked.

The inspection result is displayed: OK or Err

7. Press COLUMN to return to Key Test Mode.

Advertising