2.3 C2 Mode: Key Check

Operation Display

1. Starting Test Mode (C1)

Press ON/OFF.
Press and hold ZERO(+) while all segments are lit.

2. Entering C2 Mode

Press ZERO(+).

3. Checking Keys

Press SET.

[KEY-0] indicates that there is no key entry.

4. Checking Keys
ZERO(+) p 1 TARE(-)p 2

p 3

SET p 4 EXT. INPUTp 5 MEMORY SW p 6

5. Finishing Procedure

Press ON/OFF to finish this procedure.

OFF status

2.4 C3 Mode: Display Check 1 (Simplified Check)

Operation Display

1. Starting Test Mode (C1)

Press ON/OFF.
Press and hold ZERO(+) while all segments are lit.

2. Entering C3 Mode

Press ZERO(+) twice.

¼

3. Checking Displays

Press SET.

The display shows self-diagnostic check.

¼

4. Returning to Test Mode

Press COLUMN to return to Test Mode.