Rice Lake Ishida IGX & IGB Series - Service Manual User Manual
Page 5

Manual No. 085-3435-07
4/45
IGB/IGX Series (Overseas Specifications) Service Manual
Item Contents
IGB Series
IGX Series
Model Name
IGB-60 IGB-150 IGX-60 IGX-150
Power Source
Two dry batteries (not included with the
machine), or optional AC adapter
[Battery Life]
Conditions: No option, Temperature 20
°
C,
Relative humidity 60%RH
Two “D” size alkaline batteries (Approx. 500H
continuous use)
The required transformer is provided for
each 100VAC, 120VAC, 220VAC, or
240VAC.
Power Consumption
25mA
100VAC: 57mA
120VAC: 46mA
220VAC: 28mA
240VAC: 23mA
Display
LCD
Numerics: 6 digits, Height 25mm
Mark: Battery. Zero point, Now subtracting
tare, Stable, Weight unit (kg lb), Over,
Under, Accept
VFD
Numerics: 5 + 1/2 digits, Height 29mm
Mark: Zero point, Now subtracting tare
LED
Over, Under, Accept
Tare Subtraction
Key-in tare
Preset tare
Preset Function
[Program Mode] 10 PLUs from PLU 1 to PLU 10 (Tare weight, Upper limit, Lower limit)
Upper Limit Range
More than the lower limit, within 5 digits (99999)
Lower Limit Range
Less than the upper limit, (5 digits in case of the upper limit = 0)
Auto Power Off
[Setup Mode] None/10min./ 20min./ 30min./
40min./ 50min./ 60min.
No
Auto Preset Call-up
[Setup Mode] Function “Yes”/”No” selection (PLU 1 is called up when the power is ON.)
Battery Check Mode
Yes
No
Buzzer No
[Setup
Mode]
ON/OFF Switch
No
[Setup Mode]
Option
AC adapter (Dealer option)