Rice Lake Ishida IGX & IGB Series - Service Manual User Manual

Page 17

Advertising
background image

Manual No. 085-3435-07

16/45

IGB/IGX Series (Overseas Specifications) Service Manual

When Performing Fine Span Adjustment

1. Trimming

After span adjustment, press COLUMN while the A/D data
is displayed.

[Tri-] (Trimming) display will appear.
(This is possible even with the weight placed)

2. Trimming Up

Press ZERO(+), then [Tri-U] will be displayed.

Press ZERO(+) for the desired number of times to increase

the span.


3. Trimming Down

Press TARE(-), then [Tri-d] will be displayed.

Press TARE(-) for the desired number of times to decrease

the span.

Note

The change amount for one time may differ
depending on each machine; however,
approximately one count for one time is average.

4. Repeating Steps

Press COLUMN, then A/D data will be displayed.

Place a weight on the weighing platter, and perform

adjustment by repeating steps 1, 2, and 3 above.

5. Saving Data

After completing the adjustment, press COLUMN to save
the data.