2 9135g interface leds, 3 enable/disable llf or lle, Figure 8. 9135g interface led indicators -8 – CANOGA PERKINS 9135G SNMP Managed Gigabit Ethernet Switch User Manual

Page 16: Table 2. 9135g interface leds -8

Advertising
background image

EdgeAccess Ethernet Switch

2.7.2 9135G Interface LEDs

Table 2. 9135G Interface LEDs

LED

Status

Description

Tx (Transmit)

Off

No transmit activity

Green

Currrent transmit activity

Red

Transmitter is disabled due to LLF or LLE

Lnk (Link)

Off

The interface has not established an optical link

Green

The interface has an optical link established

Pse (Pause)

Amber

The interface is receiving too much data or too fast

LLF (Link Loss Forward) Off

Link Loss Forward is disabled

Green

Link Loss Forward is enabled

Rx

Off

No receive activity

Green

Current receive activity

Red

Remote

fault

detected

Fdx

Off

Operating as half-duplex

Green

Operating as full-duplex

Dis (Disable)

Off

Modular interface enabled

LLE (Link Loss Echo)

Off

Link Loss Echo is disabled

Green

Link Loss Echo is enabled


Figure 8. 9135G Interface LED Indicators

2.7.3 Enable/Disable LLF or LLE

You can select LLF and LLE or Remote Fault sensing in the hardware or software by specifying
hardware or software control for these functions in the user interface. For details on the user
interface, see Section 3.2.3, Port Information. LLF is limited to only one port at a time. To set these
functions on an interface module:

Step 1. Loosen the captive screws and pull the module out of the chassis.

Step 2. Locate SW1, then set it as needed:

• Switch position 1 controls LLF: On enables LLF; Off disables LLF
• Switch position 2 selects LLE or Remote Fault: On selects LLE; Off selects Remote Fault


Step 3. Insert the module in the chassis and tighten the captive screws.

Model 9135G SNMP Managed Gigabit Ethernet Switch

2-8