4 passwords, Figure 19. passwords menu -10 – CANOGA PERKINS 9135G SNMP Managed Gigabit Ethernet Switch User Manual
Page 26
![background image](/manuals/651357/26/background.png)
EdgeAccess Ethernet Switch
• SLIP IP Address enter the IP address of the Serial Line Interface Port. The SLIP and in-band
addresses must be on different networks with different network IDs.
• SLIP Subnet Mask enter the SLIP Subnet Mask
• SLIP Port Setup opens the SLIP Port Setting Menu. The suggested SLIP Port set up is:
• Baud Rate 9600
• Parity None (N)
• Stop Bits 1
• Flow Control None (N)
3.2.1.4 Passwords
The 9135G has three levels of password protection:
• Supervisor highest level, control over all menu functions
• Manager middle level, has some write access
• User
lowest level, mostly read-only, can reset some counters
When setting a new password, you may enter up to 18 characters. All letters, numbers, and characters
are legal; the password is case sensitive. Reference Figure 19.
Figure 19. Passwords Menu
Model 9135G SNMP Managed Gigabit Ethernet Switch
3-10