30 set orientation to backsight point – Leica Geosystems TPS1100 Professional Series - Applikation - Feldhandbuch (Teil 2) User Manual
Page 30
Advertising
30
Set Orientation to Backsight Point
Trav\ Define Backsight Pt
Data Job
: FILE02.GSI
A:
Search for :
PointId+E+N
Point Id
:
500
SEARC AZI INPUT SKIP VIEW
MC
Enter backsight Point Id.
To search and import backsight point from data job.
To measure and record backsight point and set the
orientation.
Continues to Traverse Menu.
For backsight
orientation given
the azimuth
F1
F1
F1
F1
F1
SEARC
F1
F1
F1
F1
F1
ALL
Trav\Measure Traverse Point
Point Id
:
500
MC
ALL
DIST
REC CONT
To keep the
currently set
orientation
1
100pr62
Backsight Point (known)
Pt500
Stn1
Advertising