Configuration – Leica Geosystems TPS1100 Professional Series - Applikation - Feldhandbuch (Teil 2) User Manual
Page 59
Advertising
59
Auto
Record
AREC\
Auto Record
MC
Configuration
SHIFT
F2
F2
F2
F2
F2
CONF
F1
F1
F1
F1
F1
CONT
Call the configuration in the first application dialog.
To exit configuration dialog.
AREC\
Configuration
TimeInterv : -----sec
MC
F3
F3
F3
F3
F3
TIME
F4
F4
F4
F4
F4
DIST
F5
F5
F5
F5
F5
ST&GO
To switch the time mode ON or OFF.
To switch the distance mode ON or OFF.
To switch the Stop & Go mode ON or OFF.
Time Interv
Time interval for automatic recording of the
measurement data.
Dist.Interv
Distance interval for automatic recording of the
measurement data.
Stop Pos.
In stability mode: range in which the prism must be
held stable during Stop Time.
Stop Time
In stability mode: time interval during which the prism
must be held stable within the range Stop Pos.
Advertising