1

26

_03

_01

_14

04

1 Condensate pan drain

6.1 Descaling

At high temperatures water separates out lime. This is deposited

on the inside of the tank. With increasing limescale build-up, the

amount of hot water inside the tank is reduced.

» Have a licensed installer descale the booster heater from

time to time. This extends the service life of the booster

heater.

» Scale cannot build up on the heat pump element.
A licensed installer who knows the local water quality will tell you

when the next maintenance appointment is due.

» Have your licensed installer check the sacrificial anode

regularly.

7. What to do if ...

7.1 ... the water heater does not deliver hot

water

» Check the water heater power supply.

» Check your fuse box for a tripped circuit breaker.

» Make sure there is a 15 A double pole circuit breaker
If the circuit breaker has tripped, reset it or replace it. Notify your

local licensed installer if the circuit breaker trips again.

» Ensure that the air intake and air discharge are unobstructed.
Excessively high ambient temperature, excessively high

temperature of the air drawn in (> 42 °C (108 °F)) or a fault in the

refrigerant circuit can result in the compressor being overloaded.

The thermal protective 'auto reset' motor switch or the high limit

'manual reset' cut-out can both shut off the compressor off.

The high limit pressure limiter must only be reset by

your licensed installer after they have removed the

cause of the relevant fault.

After a short cooling down period, the thermal protective motor

auto reset switch will restart the compressor automatically.
Notify your local licensed installer if the water heater does not

restart automatically.

7.2 ... the safety valve of the cold water supply

line is dripping

This unit can operate up to 0.48 MPa (70 psi) of inlet pressure.

Expansion water drips from the safety valve during heat-up. This

is completely normal. Notify your local licensed installer if water

still drips after heat-up has been completed.

7.3 ... the condensate drain drips

This is quite normal and always happens when the surface

temperature of the evaporator is lower than the dew point

temperature of the ambient air.

7.4 ... the power consumption is too high

Please consult a qualified licensed installer.

7.5 ... the room temperature drops excessively

The water heater operation reduces the ambient air by

1 to 3 °C (2 to 6 °F). Notify your local licensed installer if the

ambient temperature drops abnormally.

7.6 ... other faults occur

Notify your local licensed installer. Refer to the water heater

number on the type plate next to the barcode.

Type: Accelera 300/WHP 300

Heat pump:
PN (Air 42° / Water 60°):
IN (Air 42° / Water 60°):
Type of Refrigerant:
Refrigerant charge:
Max. operating pressure:
Lock rotor current:
MCA:
Rated load compressor:
Motor fan:

Order-No.: 222423

DHW-cylinder:
Additional heating element:
Max. operating pressure:
Max. operating temperature:
Type of cylinder material:
Cylinder capacity:
Test pressure storage tank:

Observe the installation manual! Tested for leaks!

Made in Germany

No.: xxxx / xxxxxx

Voltage / Frequency:
Breaker:
P (rated power input):

Limits for heat pump operation:
Maximum allowable ratings
Protection class:

Nmax

Single phase 220-240 V, 50/60 Hz
15 amp.

6 °C / +42 °C
2200 W, 9.17 A
IP 24

*222423xxxxxxxxxxxx*

1690 W
87 psi /600 kPa
168.8 °F / 76 °C
Glass lined steel
80.044 Gal /303 l
130.5 psi / 900 kPa

0.5 kW
2.17 A
R134a
1.9842 Lb. /900 g
348.1 psi /2.4 MPa
13.4 A
10.4 A
2.3 A
38 W

STIEBEL ELTRON INC
17 West Street
West Hatfield, MA 01088
USA

282209-35793

26

_03

_01

_13

57

1

1 Water heater number

8. Safety

Only qualified licensed installers should carry out installation,

initial start-up, maintenance and repair of the water heater.

8.1 General safety instructions

Use only original accessories and spare parts intended for this

water heater.

DANGER Electric shock

Disconnect the water heater from the power supply

prior to its installation.

WARNING Injury
If the pipes inside the water heater are damaged,

leaking refrigerant gas can result in severe physical

freezer burns.

Do not inhale refrigerant. Immediately vent the room

thoroughly.

»

Wear safety goggles and gloves during water heater

installation.