16.4 Technical Data

Model

Heat pump water heater

Type

Accelera 300

Part number

222423

Version

With passive defrosting and booster heater

Operating details

Lower application limit for heat pump operation
(air temperature)

°C (°F)

6 (42.8)

Upper application limit for heat pump operation
(air temperature)

°C (°F)

42 (107.6)

Hot water temperature, heat pump

°C (°F)

60 (140)

Hot water temperature, booster heater

°C (°F)

60 (140)

Air flow rate

m

3

/h (CFMs)

550 (324)

Tank capacity

l (Gal)

303 (80.044)

Refrigerant

R 134a

Refrigerant / filling weight

g (oz)

900 (32)

Water heater height (minimum)

mm (inch)

1865 (73.43)

Water heater height (maximum)

mm (inch)

1903 (74.92)

Water heater diameter

mm (inch)

660 (25.98)

Dimension when tilted incl. packaging

mm (inch)

2225 (87.60)

Dimension when tilted, excl. top packaging

mm (inch)

2150 (84.65)

Dimension when tilted, excl. wooden pallet and top packaging

mm (inch)

2030 (79.92)

Dimension when tilted, excl. packaging

mm (inch)

1990 (78.35)

Weight (dry tank)

kg (lb)

130 (287)

Weight (wet)

kg (lb)

432 (950)

Water connection with adaptor

Union to 3/4"

Condensate drain

3/4"

Condenser

Rollbond safety heat exchanger

Permissible operating pressure, low (cold) side*

MPa (Psi)

0.6 (87)

Permissible positive pressure, high (hot) side*

MPa (Psi)

2.4 (348.1)

Sound pressure level (spl)

dB(A)

55.2

Maximum inlet water temperature

°F (°C)

140 (60)