Installation installation, Installation – STIEBEL ELTRON Accelera 300 User Manual

Page 14

Advertising
background image

14

| ACCELERA® 300 HEAT PUMP WATER HEATER

WWW.STIEBEL-ELTRON-USA.COM

INSTALLATION

INSTALLATION

8

7

9

10

26

_03

_02

_14

05

7 Capacitor

8 Fan

9 Evaporator

10 Defrost sensor

The hot water thermostat temperature is preset at the

factory.

Where customers require a lower hot water

temperature, the thermostat settings of the heat pump

and the booster heater can be reduced.

A sacrificial anode rod is installed in the top of the water heater. (6)

9.1 Standard delivery

- Accelera 300 heat pump water heater

- Two adaptors, Union to ¾"

- Two union gaskets

9.2 Special accessories

Description

Part number

Anode rod

278235

Segmented anode rod

143498

10. Installation

CAUTION Injury

Incorrect installation can result in severe injuries and

material losses.

Prior to installation ensure you have adequate space

for the work to be carried out.

Handle components with sharp edges carefully.

The sheet steel casing of the water heater is not

designed to withstand heavy forces.

Handle and install the water heater with care.

10.1 Installation location

DANGER Explosion

Never install the water heater in rooms where it is

at risk from explosions as a result of dust, gases or

vapors.

WARNING Injury

The room where the water heater is to be installed

must have a load-bearing floor. There is a risk of

the water heater breaking through the floor if the

substrate has insufficient load-bearing capacity. The

wet weight of the water heater is approx. 430 kg (950

lb).

If the floor offers inadequate load-bearing capacity,

there is a risk of the water heater breaking through

the floor, resulting in a risk to life.

Risk of frost damage

Install the water heater only in an area free from the

risk of frost. When the water heater is not in use and

there is a risk of frost, the water inside the water tank

can freeze and damage the tank.

- Never install the water heater in areas where the air

temperature regularly drops below 6 °C (42 °F) or rises above

42 °C (108 °F).

- To prevent nuisance through operating noise, never install

the water heater in the vicinity of bedrooms. Prevent noise

emissions towards a neighbor.

- Allow adequate space around the water heater for

installation, maintenance and cleaning tasks.

With internal installations, also observe the following:

- The available floor area in the installation room must be at

least 6 m² (10' x 10' - 100 ft²). The room volume must not be

less than 13 m³ (500 ft³).

- The water heater must not be restricted by walls and

ceilings. The required minimum clearances are specified in

chapter "Positioning the water heater/positioning conditions"

(see chapter 10.5, "Positioning the water heater")..

- Observe that the room temperature will drop by 1 to 3 °C (2

to 6 °F) as a result of the water heater operation.

- When installing the water heater in a furnace room, ensure

that the furnace operation will not be impaired.

- To keep line runs as short as possible, we recommend that

the water heater is installed near the kitchen or bathroom.