| ACCELERA® 300 HEAT PUMP WATER HEATER

WWW.STIEBEL-ELTRON-USA.COM

GENERAL INFORMATION

QUICK START-UP GUIDE

GENERAL INFORMATION

Please read

Read these instructions carefully and retain them for

future reference. If the water heater is passed on to

a third party please hand these instructions to the

new user.

This manual includes important information regarding the safe

and efficient handling of the water heater. Keep this manual with

the water heater at all times.
Work must only be carried out by a licensed installer who has read

and understands these instructions. All federal, state, and local

codes must be followed. Failure to do so may result in equipment

failure, serious injury, or death.
While working on the water heater, disconnect the power supply.
Illustrations in these instructions are designed to aid a general

understanding and may deviate from the actual water heater

version. No claims can be derived from such illustrations.
Limited liability:
We have collated all details and information in this manual in due

consideration of applicable standards and regulations, the state of

the art and our long-term know-how and experience.
Losses due to the following are excluded from our liability:

- Non-observance of these instructions

- Incorrect use

- Installation of the water heater by unqualified personnel

- Unauthorized modifications

- Technical modifications

- Use of unauthorized spare parts

Copyright:
These operating and installation instructions are subject to

copyright.
Transferring these instructions to third parties, copying of any

kind, either in total or extracts therefrom, as well as their use

and/or conveying its contents are prohibited without our written

consent.
Contraventions are liable to claims for compensation. Further

claims are reserved.

We hold the copyright:
STIEBEL ELTRON Inc.

17 West Street | West Hatfield MA 01088

Tel. 413-247-3380 | Fax 413-247-3369

Email [email protected]

www.stiebel-eltron-usa.com

Should you have any question regarding the installation or

operation of the water heater, please contact our customer service.

Tel. (USA) 800-582-8423 or 413-247-3380

Please record your serial number and information

Serial No.: ____________________________________________________________________

Date of Purchase:____________________________________________________________

Accelera

®

300 Quick Start-up Guide

A.

OVERVIEW: This water heater hooks up like any other electric water heater, with a few minor exceptions. Be sure to follow

all state and local codes during installation. This page is not intended to be a substitute for the installation manual. Be

sure to follow all safety precautions.

B.

UNPACKING: DO NOT unpack water heater unit until it is located at the point of installation. Follow all instructions in the

manual and be sure to use caution, as this unit is top heavy. DO NOT lay the unit down and DO NOT jar or tip the unit past

45 degrees on the hand truck.

See: 10.6

C.

INSTALLATION / WATER:

a. Location: Find a suitable location according to the manual. Minimum area is 10’ x 10’ x 8’. Be sure vents are parallel to

the wall with the fan facing the most open area along that wall. Please note: a drain pan is recommended.

See: 10.6

b. 3/4” Inlet from union provided. For hook-up, follow all state and local codes for check valves, expansion tanks, shut off

valves, gauges, etc. Install a 70 psi pressure reduction valve.

Please note: water pressure should not exceed 0.48 MPa (70 psi).

See: 10.7

c. 3/4” Outlet from union to hot water line.

d. Install T&P Relief valve (supplied). Please note: 0.69 MPa / 99 °C (100 psi / 210 °F).

D.

CONDENSATE DRAIN: Goes directly into a drain or use a condensate pump to drain into a suitable location. See: 10.6.1

E.

FILL & FLUSH TANK: Run water and be sure tank is full prior to turning on the electricity.

F.

INSTALLATION / ELECTRICAL: Use a 240 Volt / 15 Amp double pole breaker and connect to water heater L1, L2, and

Ground.

See: 16.2

!

WITHIN ABOUT 5 HOURS OF START-UP TIME, EXHAUST
AIR FLOW SHOULD BE APPROXIMATELY -14,4 °C (6 °F)
LESS THAN THE INLET SIDE.

CAUTION: RISK OF SCALDING.

THERE IS A RISK OF SCALDING AT OUTLET

TEMPERATURES EXCEEDING 43 °C (110 °F) RISK OF

SCALDING