OPERATION

WATER HEATER DESCRIPTION

EN

GL

ISH

WWW.STIEBEL-ELTRON-USA.COM

ACCELERA® 300 HEAT PUMP WATER HEATER |

13

WARNING Injury

Moving parts represent a risk of injury.

»

Before opening the water heater, ensure that the fan

has come to a complete standstill.

8.2 Incorrect use

The following are not permitted:

- Do not install the water heater on non-load bearing floors

- Do not install the water heater where it is at risk from frost

- Do not install in rooms where the water heater is at risk from

explosions as a result of dust, gases or vapors

- Do not ignore safety clearances and safety zones

- Do not incorrectly install the power connection

- Do not operate the water heater with the tank empty

- Do not operate the water heater with an open casing

- Do not heat anything other than potable water

- Do not fill with any other Freon, use only R134A

8.3 Qualification

WARNING Injury

Incorrect handling can result in severe injuries and

material losses. Inadequately qualified personnel

cannot assess the impending danger.

Have only personnel mentioned in the appropriate

sections of this manual carry out specific measures.

In this manual, such qualified individuals will be described as the

"licensed installer".
Licensed installers are responsible for adherence to all currently

applicable regulations during installation and initial start-up.

8.3.1 Licensed installer

Licensed installers are specially trained in their field. Licensed

installers work on systems on the basis of their training, knowledge

and experience, as well as their knowledge of applicable standards

and regulations. They are able on their own to recognize and

prevent possible problems.

8.3.2 Electrician (licensed)

An electrician is a licensed installer who meets the above

requirements with regard to electrical installations.

8.3.3 Plumber (licensed)

A plumber is a licensed installer who meets the above requirements

with regard to water-related installations.

8.3.4 Customer service

For customer service inquiries, please contact Stiebel Eltron

directly at 1-800-582-8423, ext. 25 or ext. 33.

8.4 Instructions, standards and regulations

Follow all national, state, and local codes.

Observe the regulations of your local energy and water supply

utilities.
The following standards were taken into account:
UL 499, UL 1995, UL 94-5 VA, UL 174
IEC 60335-1-2-40, IEC 61000-3-2; 1995

IEC 61000-3-3, IEC 55014-1 IEC 55014-2
EMC Directive 89/336/EEC
EN 255 T3
Read the water heater type plate and the chapter "Specification".

8.5 Water installation

The following materials may be used:

- Cold water line: steel, copper or plastic pipework.

- Hot water line: copper or plastic pipework.

» Ensure that no contamination reaches the water heater

through the pipework.

8.6 Electrical installation

Protect the water heater electrically with a 15 A double pole circuit

breaker.
Where the water heater is permanently connected to the power

supply, it must be able to be separated from the mains power

supply by an additional isolator that disconnects all poles with

at least 3 mm (0.12 ") contact separation. For this purpose, use

contractors, circuit breakers, fuses, etc. on site.
In case of a fault, the safety equipment interrupts the relevant

power circuit.

9. Water heater description

3

2

1

4

5

26

_03

_02

_14

04

1 High limit safety cut-out - manual reset

2 Compressor

3 Condensate drain

4 Filter dryer

5 Service valve, high pressure

6 Sacrificial anode

6