![background image](/manuals/654386/17/background.png)
EN
GL
ISH
WWW.STIEBEL-ELTRON-USA.COM
ACCELERA® 300 HEAT PUMP WATER HEATER |
17
INSTALLATION
INSTALLATION
26
_03
_01
_13
84
» Push two polystyrene
®
installation aids with the step-shaped
corner underneath the water heater. The water heater is
subsequently set and tilted onto this profile. Ensure that you
do not set the water heater down in the area of the joint edge
of the sheet steel jacket, but at least 150 mm (6") along.
26
_03
_01
_13
88
» Tilt the water heater that has been set down on the
polystyrene
®
installation aids.
» Remove the remaining floor semi-shell.
» In the tilted state of the water heater, wind out the second
and third leveling foot, but not by more than 30 mm (1.1").
» In both cases, tighten the locking nut against the bottom
cover.
» Position the water heater on the three leveling feet.
» Level the water heater vertically by adjusting the three
leveling feet.
» Remove any packaging that remains on the water heater.
» Install condensate drain elbow.
10.6.1 Condensate drain
26
_03
_01
_11
27
1
< 8
89 (
35
")
2
3
4
5
6
1 Condensate drain or
2 Drain pan connected to drain
3 T&P valve
4 Cold water connection
5 Hot water connection
6 Condensate spillover
The condensate drain is located on the side of the water heater.
This is where you can connect a drain hose.
When installing the unit outdoors, the condensate can drain off
freely.
For indoor installation, the condensate can be routed into a floor
drain or routed through the wall up to 889 mm (35") (see diagram
above).
If required, install a condensate pump.
To ensure the condensate drains correctly, never kink
the hose.