2000 Series Tractors

112

6.

Regulator/rectifier check: See Figure 7.30.

6a.

Check the ground.

With the engine running and the stator leads re-
connected to the regulator/rectifier, perform a
ground-side voltage-drop test from the regulator/
rectifier to the engine block.

If the voltage reading is greater than 0.1 Volts
D.C., replace or properly fasten the ground wire
that connects the regulator/rectifier to the engine
block. Retest to confirm good connection.

6b.

Bench Test: See Figure 7.31.

Set a digital multi-meter to read on the X100

Ω

scale.

With the key OFF and the fuse removed, unplug
all the wires from the regulator/rectifier.

Remove the regulator/rectifier from the engine
(not strictly necessary, but provides easy
access).

Make the resistance tests described in the
accompanying table.

B+ is the D.C. terminal

A.C.1 is the A.C. terminal nearest B+

A.C.2 is the A.C. terminal furthest from B+

Figure 7.30

Figure 7.31

A.C.2 A.C.1 B+