2. Check the freewheel lever is fully engaged (see page

12 ). If it is engaged you should not be able to push
your machine. If disengaged, 9 bars will flash on your
battery condition mater with the speed lever pressed.

1. Turn off the power 'on' key switch.
2. Inform your authorised

dealer.

If your Freerider does not slow down or behaves erratically:

Freerider

If you find for any reason your Scooter

does not reduce speed when you let go of the forward-
reverse speed lever . Switch your Scooter 'off' with the
on/off key. The parking brake will activate immediately and
stop your Scooter. Beware the scooter will stop very
suddenly, brace yourself with the handlebars, sit back in
your seat.

This operation should only be carried out in an

emergency; continual use of this facility will damage the drive
transmission and motor brake.

The speed controller system incorporates a sophisticated
micro-processor design (Fig 42). It is located under the rear

Warning:

Warning:

Inform your authorised Freerider dealer before using your
machine again.

Warning:

Freerider

If you feel for any reason that your Scooter is not

driving correctly or making an unusual noise, stop using the
machine. Be safe, contact your

dealer, he will be

able to advise you.

IMPORTANT SPEED CONTROLLER
INFORMATION

If your Freerider does not slow down or behaves erratically:

Freerider

Warning:

Warning:

Inform your authorised Freerider dealer before using your
machine again.

Warning:

Freerider

IMPORTANT SPEED CONTROLLER
INFORMATION

Body cover of your Scooter ( see fig 41). The in-built
micro-controller continually monitors the
Scooter's systems to ensure safe and reliable operation.

Speed control system integrity
Internal voltages and circuits
Motor voltages and circuits
Freewheel speed limiting downhill.
Battery voltage

When the battery voltage is low, the 'battery gauge status'
indicator bar light, situated on the control console ( fig 11,
page 9 ) will flash one red bar slowly as a warning to recharge
your batteries. If the 'speed controller' detects a fault the
battery gauge/status indicator will display a number of bar
flashes indicating the nature of the fault.

For example, the controller will not operate if the speed lever
is not in the neutral position ( fig 12, page 11) when the
Scooter is switched 'on'. Return the speed lever to the neutral
position, when the Scooter will be allowed to operate normally
once again. This safety detection is indicated by a steady
rippling display on the battery gauge ( see also Fault Diagnosis
below ).

If your Scooter is turned 'on' but not operated for a set period
of time ( 15 minutes approx )the speed controller system will
automatically turn itself 'off' to conserve valuable battery
energy, you will note the battery gauge is switched off. It can
be turned on again by turning the on/off switch to 'off' and
then to 'on' again.

A reversing buzzer is provided for when you are driving in a
reverse direction. This is an important safety feature to make
other people aware of your change of direction.

Freerider

SAFETY CONDITIONS MONITORED INCLUDE

Freerider

SAFETY CONDITIONS MONITORED INCLUDE

FLASH CODE
(No. Of flashes)

FLASH CODE
(No. Of flashes)

Battery needs recharging

Motor disconnected

Motor wiring fault

Not used

Not used

Inhibit active

Speed pot error

Possible controller fault

Motor solenoid brake fault

High battery voltage

STATUS FAULT CODES

-The number of bar segments flashing on the battery gauge display indicates the type of fault

STATUS FAULT CODES

1 Flash

2 Flashes

3 Flashes

4 Flashes

5 Flashes

6 Flashes

7 Flashes

8 Flashes

9 Flashes

10 Flashes

The battery voltage has dropped below 16volits in
neutral. Recharge the batteries. Check the battery
condition and the connections.

Motor plug disconnected. Check motor, motor
connectors and wiring.

Motor short or wiring fault. Check motor plug check
motor brushes change motor. If above checks fail to
correct fault, change controller.

Battery charger connected.

Driving inhibited

Drive inhibited

Drive inhibited

Drive inhibited

Drive inhibited

Drive inhibited

Drive inhibited

Drive inhibited

FAULT DISPLAYED
BY PROGRAMMER

FAULT DISPLAYED
BY PROGRAMMER

FREERIDER SCOOTER
CONDITION

FREERIDER SCOOTER
CONDITION

COMMENT

Check speed pot wiring for open or short circuits.
Speed pot may not be correctly set up . Contact your
Service Agent.

Fault detected in main controller-contact Service Agent..

Fault detected in solenoid brake or connection to it or
freewheel lever activated.

Battery voltage at the controller is greater than 38
volts. Check condition of batteries and connections.
Supect a charger malfunction.

(speed control lever)