3.2.1 CONFIGURATION: AUTOMATIC LINE FEED AFTER CARRIAGE RETURN.



1. Begin with the ENTER light OFF.

2. Turn the thumbwheel switch to position 1.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 1.
5. Press the ENTER switch. The ENTER light turns on.
6. Turn the thumbwheel switch to position:
0 for AUTO LF --- OFF
1 for AUTO LF --- ON
7. Press the ENTER switch. The ENTER light turns off.



---------- SET AUTO LF AFTER CARRIAGE RETURN ---------



FLASH ON OFF (Enter Light)
Auto lf OFF 1 1 0 (Thumbwheel Switch)
Auto lf ON 1 1 1 (Thumbwheel Switch

)




3.2.2 CONFIGURATION: AUTOMATIC FORM FEED.



1. Begin with the ENTER light OFF.

2. Turn the thumbwheel switch to position 1.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 2.
5. Press the ENTER switch. The ENTER light turns on.
6. Turn the thumbwheel switch to position:
0 for AUTO FORM FEED --- OFF
1 for AUTO FORM FEED --- ON
7. Press the ENTER switch. The ENTER light turns off.




--------------- SET AUTO FORM FEED ---------------



FLASH ON OFF (Enter Light)
Auto Form Feed OFF 1 3 0 (Thumbwheel Switch)
Auto Form Feed ON 1 3 1 (Thumbwheel Switch)



REMEMBER:

Return the thumbwheel switch to the correct mode position after configuration.