3.3.5 CONFIGURATION: SEQUENCE NUMBER.


The sequence number is enabled when it is set. Setting the sequence
number to 00000 disables sequence numbering.
1. Begin with the ENTER light OFF.
2. Turn the thumbwheel switch to position 2.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 6.
5. Press the ENTER switch. The ENTER light turns on.
6. Enter a 5 digit number by selecting numbers on the thumbwheel
and pressing the ENTER switch.
7. The ENTER light turns off.



------------------ SET SEQUENCE NUMBER -----------------

FLASH ON ON ON ON ON OFF (Enter Light)
Sequence 2 6 X X X X X (Thumbwheel Switch)
Number (XXXXX is a 5 digit ticket number

)

































REMEMBER:

Return the thumbwheel switch to the correct mode position

after configuration