Industrial Data Systems IDS 160 User Manual

Page 32

Advertising
background image

3.4.5 CONFIGURATION: TRIP LEVEL.

The default setting for the trip level is 5000. To
set the trip level to another weight do the following:

1. Begin with the ENTER light OFF.
2. Turn the thumbwheel switch to position 7.
3. Press the ENTER switch. The ENTER light begins flashing.
4. Turn the thumbwheel switch to position 5.
5. Press the ENTER switch. The ENTER light turns on.
6. Turn the thumbwheel switch to position:

0 for 500

1 for 1000
2 for 2000
3 for 5000 (default)

7. Press the ENTER switch. The ENTER light turns off.


------------------ TRIP LEVEL -----------------


TRIP LEVEL FLASH ON OFF (Enter Light)

Set 500 7 5 0 (Thumbwheel Switch)
Set 1000 7 5 1 (Thumbwheel Switch)
Set 2000 7 5 2 (Thumbwheel Switch)
Set 5000 7 5 3 (Thumbwheel Switch)


























REMEMBER:

Return the thumbwheel switch to the correct mode position

after configuration