E CZ-V21A(P)/V22A(P)-IM

MOUNTING THE AMPLIFIER UNIT

CONNECTING SEVERAL AMPLIFIER UNITS

Up to three sub-units CZ-V22A(P) can be mounted adjacent to the main unit CZ-
V21A(P). By connecting several units, the number of power cables can be
reduced.

1

Remove the protection cover on the side of the

amplifier.

2

Mount the sub-unit on the DIN rail.

3

Connect the sub unit to

the connector on the main
unit by sliding the sub unit
toward the main unit until a
clicking sound is heard.

4

Mount the end units on both

sides.
Fasten the screws on the top
of the end units (at two posi-
tions on both end units) with
the Philips screwdriver.

MOUNTING THE SENSOR HEAD

1

Open the dust cover.

2

Tilt the fixing levers.

3

Insert the fiber cable and the connector of the sensor head into the corre-
sponding ports.
Be sure to insert the fiber cable until it reaches the deepest end (the
inserted length: about 20 mm).
* The CZ-H52 is not supplied with the fiber cable.

Attach the supplied cover seal on the fiber cable insertion slot when
using the CZ-H52.

4

Lock them with the fixing levers.

5

Route the cable of the connector under the fixing lever.

When the cable of the sensor head is too long

1

Fabricate the cable end as shown in the figure.

2

Tilt the lid of the connector in the direction of the arrow indicated on its
left-hand side, and open the connector.

3

Insert the wires to the deepest end with the shielded wires bent upward.
Bend the shielded wires along the grooves in the direction of the arrows.
Be sure to match the colors of the sticker on the connector with those of
the shielded wires.

4

Close the connector to crimp down the wires, and tilt the top to lock.

5

Trim off the wires sticking out of the connector by using a nipper or the
like.

Mounting on a DIN rail

Hook the claw located on the bottom
of the amplifier unit to the DIN rail.
While pushing the amplifier unit in
the direction of the arrow 1, push it
down in the direction of the arrow 2.
To dismount the amplifier unit, while
pushing the main body in the direc-
tion of the arrow 1, raise the body in
the direction of the arrow 3.

2

3

1

Mounting on a bracket

Mount the amplifier unit using the
supplied mounting bracket as
shown in the figure.

2

1

Note

Limit the reconnection to two times.

A

B

BA

NK

1

2

3

4

C

OU

T

1

2

3

4

Connector
port

Fiber cable port

10 mm or more

Shielded wire

Core

90°

Red

White

Advertising