E CZ-V21A(P)/V22A(P)-IM

MENU SELECTION

Pressing the MODE button for three seconds or more displays the menu, from
which each mode can be configured.
To exit the menu during setting, press the MODE button again for three sec-
onds or more.

* For the method of selection, refer to page 6.

Selecting a function (detection mode)

Select by pressing UP or DOWN.

• C mode: Detects color based on

color components

• C+I mode: Detects color based

on color components

and light intensity

• Super I mode: Detects color based

on light intensity

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

Selecting the power saving function (Eco mode)

Select by pressing UP or DOWN.

• Normal use

• Enables the power saving function

Selecting the shift function

Select by pressing UP or DOWN.

• Normal use

• Enables the shift function

Selecting the attenuation mode

Select by pressing UP or DOWN.

• Normal use

• Lowers the light receiving sensitivity

Setting the shift target value

Set the value by pressing UP

or DOWN.

Selecting an access mode

Select by pressing UP or DOWN.

• Displays the basic menu only.

• Displays all menus.

Selecting calibration mode

Select by pressing UP or DOWN.

When the C/C+I mode is selected

• 1-point calibration

• 2-point calibration

• Pinpoint calibration

When the CZ-H72 is used

• 2-point calibration

• Base calibration

• Film calibration

Press MODE for three seconds or more

Press MODE

Press MODE

Press MODE

Press MODE

Press MODE

Press MODE

Press MODE

End of the basic

menu display

Menu display

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

Setting the timer time

Set by pressing UP or

DOWN.

Selecting a timer mode

(can be set for each bank)*

Select by pressing UP or DOWN.

• Timer OFF

• On-delay

• Off-delay

• One shot

Press MODE

Press MODE

When the access mode is selected as FULL

When timer
is selected
as OFF

When timer is
other than OFF

When the Super
I detection mode
is selected or the
CZ-H52 is used

When the C/C+I
detection mode is
selected or the
CZ-H72 is used

When the C/C+I
detection mode is
selected or the
CZ-H72 is used

When the Super I detection
mode is selected or the
CZ-H52/H72 is used

When the
shift function
is selected
as off

When the shift
function is
selected as on

End of menu
display

A

B

BANK

1 2 3 4

C

A

B

BANK

1 2 3 4

C

Selecting a power mode (response time)

Select by pressing UP or DOWN.

• HIGH SPEED: 200

µs

• FINE: 1ms

• TURBO: 4ms

• SUPER: 8ms

Press MODE

Selecting an output mode

(can be set for each channel)*

Select by pressing UP or DOWN.

• Turns on at light green

(Turns on when the light

enters)

• Turns on at a color other

than light green

(Turns on when the light

is shielded)

The display inside the parentheses is when the Super
I mode is selected or the CZ-H52/H72 is used.

When using
the CZ-H52/H72

When using the
CZ-H32/H35S/H37S

Advertising
This manual is related to the following products: