How to set up each mode (models other than lv-s31), End program, E lv-s-im – KEYENCE LV-SB User Manual

Page 7: B8 7 6 5

Advertising
background image

7

E LV-S-IM

How to Set up Each Mode (Models other than LV-S31)

The settings of Output 1 and 2 can be divided into common settings and indi-
vidual settings depending on the modes. Change the mode by using the
channel selection switch. To exit the mode setting while it is not completely
finished, press the MODE button for over 2 seconds. Refer to page 8 when
using the LV-S31.

A

b

a

OR

When Output 2 is

set, Alarm output is

selected, and

"Auto" is selected

When Timer

OFF

is selected

When other
setting than

Timer OFF

is selected

When Output 1 is set

and zero datum

calibration is selected

When a mode

Normal or

Area detection

is selected.

When a mode

DSC is

selected.

When a mode other

than Normal, DSC,

or Area detection

is selected

(If the sensor head is “LV-S41/S41L” )

A

B

B

* Cannot be selected when LV-S62/S63 is being used.

When Output 2

is set.

When zero

datum calibration

is selected for

Output 1

B

When a mode DSC is

selected for Output 1

and a mode Normal is

selected for Output 2

C

End of the basic

menu display

When selecting a timer mode,
If other setting than *1 is selected

→ a

If *1 is selected

→ b

1

Selecting output

2

3

Selecting the Timer mode

4

Selecting the detection mode

Selecting the detection operation

Press the or button to select.

• L-on Mainly for reflective type

[light intensity with workpiece >

light intensity without workpiece]

(The output is on when the light

enters)

• d-on Mainly for thrubeam type

[light intensity with workpiece <

light intensity without workpiece]

(The output is on when the light

is blocked.)

Output 1/2 individual setting

Output 1/2 common

Output 1/2 individual setting

Selecting the power mode (response time)

Press the or button to select.

• Timer OFF

• OFF delay

• ON delay

• One-shot

• ON delay, OFF delay *1

• ON delay, one-shot *1

Output 1/2 individual setting*

Press the or button to select.

• Normal (light intensity) mode

• Area detection mode

• Area detection mode

• Detects the rising edge of the received light intensity.

• Detects the falling edge of the received light intensity.

• Detects both the rising and falling edges

of the received light intensity

The % calibration function cannot be used when the
DSC function is turned on or the zero datum
calibration is being used.
The shift function cannot be used when the DSC
function is turned on or the zero datum calibration is
being used.

Timer setting

Press the or button to select.

Can be set between 0.1 and 5000 ms.

When *1 is selected, the ON delay

timer is activated.

Timer setting 2

Sets an OFF delay (one-shot) time.

Press the or button to select.

Can be set between 0.1 and

5000 ms.

Selecting the derivation time

Press the or button to select.

The time can be selected from 0.25/0.5/1/2.5/

5/10/25/50/100 ms. (The available times vary

depending on the power mode.)

When the power mode is changed, redo the calibration.

Press for two seconds
or more

MODE

Press the or button to select.

• Turns ON while the light enters.

• Turns ON while the light is shielded.

Press the or button to select.

• HIGH SPEED:80 µs

• FINE:250s

• TURBO:500s

• SUPER:2 ms

• ULTRA:4 ms

MODE

MODE

MODE

MODE

MODE

MODE

MODE

C

C

End program

When %

calibration
is selected

When zero datum

calibration are selected

When zero datum
calibration or % or

DSC

calibration is selected

When OFF

is selected

When ON is

selected

When OFF

is selected

When ON is

selected

When DSC mode,

display scaling,

or zero datum
calibration are

selected

B

B

B

8

7

6

5

Selecting the sensitivity selecting method

Setting the display scaling

Setting the shift function

Selecting the control input function

Press the or button to select.

• Updates the peak/bottom value every time that the

current light intensity is less than or more than the set value

• Displays the maximum and minimum peak values

since the power was turned on (total number)

• Displays the maximum and minimum bottom values

since the power was turned on (total number)

• Displays the minimum peak value and the maximum

bottom value since the power was turned on (total number).

• Displays the maximum peak value and the minimum bottom

value since the power was turned on (total number).

9

Selecting the hold function

11

Selecting the number of digits of light intensity display

Press the or button to select.

• Normal screen display mode

• Full screen display mode

10

Selecting the display mode

Selecting the correction speed

Press the or button to select.

The correction is made faster as

the number becomes larger (1 to 3).

(Select 1 for normal cases.)

Selecting the operation for control output 2

Press the or button to select.

• Uses normal operations for

control output 2.

• Uses alarm output for control

output 2.


Setting the range for alarm output level

Press the or button to select.

Set in the range between 0 and 100P.

* Normally use the setting at 50%.

Mode LEv1 LEv2 LEv3

Correction 104.86s

1.64s

25.6ms

speed

Output 1/2 common

Press the or button to select.

• Normal sensitivity setting

• % calibration

Output 1/2 common

Output 1/2 common

Output 1/2 common

Output 1/2 common

Output 1/2 common

Output 1/2 common

Setting the display scaling target value

Press the or button to select.

It can be set by the unit of 100.

Setting the shift target value

Press the or button to select.

It can be set by the unit of 1.

Setting the target value of the %

calibration

Press the or button to select.

From –99% to +99% can be set.

Press the or button to select.

• Normal display

• Display scaling

Press the or button to select.

• Do not use shift

• Use shift

Press the or button to select.

• Does not use the control input

• External calibration

• Bank selection

• Laser emission stop

Press the or button to select.

• Four-digit display (the setting value is also displayed)

• Five-digit display

MODE

MODE

MODE

MODE

MODE

MODE

MODE

MODE

MODE

MODE

MODE

* When Area detection mode is selected in "4.Selecting the detection mode", "----" is displayed in

the Output 2 setting and Output 2 cannot be selected.
If a mode other than the Normal/Dsct Area detection mode is selected for either Output 1 or 2, the
setting of item 5 or 6 or 7 cannot be selected for both Output 1 and 2.