E LV-S-IM

When using the LV-S31

Toggling the Display

When using a model other than LV-S31

When "duAl" is selected for the number of digits of light intensity dis-

play and "Std" is selected for display mode

* The displayed number indicates the following type of alarm.

For more information about remedies to errors, see "Error indication" on page 10.

1: Over DSC correction limit
2: DSC small fluctuation detection
3: Invalid DSC EEPROM contents
4: Over fluctuation width during zero datum calibration
5: DSC speed limit alarm

When "duAl" is selected for the number of digits of light intensity dis-

play and "FuLL" is selected for display mode

*1

The received light intensity is displayed in percentage with reference to
the setting value.

*2

Its stability is indicated between 85 to 115 %. The number is varied by
the unit of 5 %.

*3 The peak- and bottom-hold values since the power-on are displayed.

The hold values can be reset by pressing the manual button.

When "rE" is selected for the number of digits of light intensity display

When using the LV-S31

Selecting the shift function input time

Press the or button to select.

• 5ms

• 20ms

The input time is fixed to 20 ms for all other

functions.

Selecting the memory of value set by an

external input while using the shift function

Press the or button to select.

• Saves the value *1

• Does not save the value (clears data at power-off)
*1 Data can be saved up to one million times.

MODE

MODE

MODE

Selecting the Power saving function (Eco mode)

Press the or button to select.

• Normal use

• Eco-half

• Eco-all

Press , , and for three seconds or more at the same time.

MODE

SET

(End Program)

(The display shown to the left appears after " " is
displayed during zero datum calibration)

When zero datum calibration is completed without errors

(The display shown to the left appears after " " is
displayed during zero datum calibration)

When zero datum calibration is completed with errors

Alarm contents*

When "Auto" is selected for the operation of control output 2 and
the channel setting is switched to "2"

When zero datum calibration is not selected

Setting value Current value

Margin

Current value

Press

MODE

When zero datum calibration is selected

Press

MODE

Setting value Current value

after zero datum
calibration

Margin

Current value
before zero datum
calibration

When zero datum calibration is selected

Setting value

Current value

Margin*

1

Current value

Bar display*

2

Current value

Output status

Power mode

Peak value

margin

Bottom value

margin*

3

Peak value

Bottom value*

3

Flashes
alternately

Flashes
alternately

Press

MODE

Press

MODE

Press

MODE

Press

MODE

Press

MODE

Press

MODE

When zero datum calibration is selected

Current value after
zero datum calibration

Current value after
zero datum calibration

Margin*

1

Current value before
zero datum calibration

Bar display*

2

Current value after
zero datum calibration

Output status

Power mode

Peak value

margin

Bottom value

margin*

3

Peak value before
zero datum calibration

Bottom value before
zero datum calibration

Flashes
alternately

Flashes
alternately

Press

MODE

Press

MODE

Press

MODE

Press

MODE

Press

MODE

Press

MODE

Current value before
zero datum calibration

Current value before
zero datum calibration

Press

MODE

Current value

Press

MODE

Peak-hold value

Bottom-hold value

Flashes
alternately

Setting value Current value

Peak value

Bottom value

Position display

Flashes
alternately

Press

MODE

Press

MODE

Press

MODE

Digital display (The position of the target from the center position
[5000] is displayed in number.)

Outside of the detection range

The workpiece is near the sensor with reference
to the digital display range.

With 5000 being the middle, the value
increases as the distance from the sensor increases.

The workpiece is far from the sensor with reference to
the digital display range.

Outside of the detection range

Position display (The position of the target with reference to the
center position is displayed.)

Outside of the detection range

Outside of the detection range

The number of bars increases as the distance from
the sensor increases, taking the state of "A" as the
center.
When adjusting the center position with the trimmer
on the sensor head, adjust it to the state of "A".

A

(1)

(2)

(1)

(2)

(3) The peak/bottom hold value since the power is turned on is displayed.

Pressing the Manual button can reset the hold value.

(3)