How to set up each mode (lv-s31), How to set up special modes, End program) – KEYENCE LV-SB User Manual

Page 8: E lv-s-im, When using a model other than lv-s31

Advertising
background image

8

E LV-S-IM

How to Set up Each Mode (LV-S31)

The settings of Output 1 and 2 can be divided into common settings and indi-
vidual settings depending on the modes. Change the mode by using the
channel selection switch. To exit the mode setting while it is not completely
finished, press the MODE button for over 2 seconds.

How to set up special modes

When using a model other than LV-S31

When Std is selected

When

HSP is

selected

b

a

When Timer

OFF

is selected

When other
setting than

Timer OFF

is selected

OR

Press for two
seconds or more

MODE

End of the basic

menu display

When selecting a timer mode,
If other setting than *1 is selected

→ a

If *1 is selected

→ b

1

Selecting output

Press the or button to select.

• Turns on the output nearer to the sensor.

• Turns on the output farther to the sensor.

Output 1/2 individual setting

4

Selecting the timer mode

Press the or button to select.

• Timer OFF

• OFF delay

• ON delay

• One-shot

• ON delay, OFF delay *1

• ON delay, One-shot *1

Output 1/2 individual setting

5

Selecting the detection mode

Press the or button to select.

• Normal detection mode

• Area detection mode

Output 1/2 individual setting

2

Selecting the power mode

Press the or button to select.

• Normal mode

• High-speed mode (response time 250 µs)

Output 1/2 common

3

Selecting the response time

Press the or button to select.

Varies depending on the power mode.

Output 1/2 common

When the power mode is HSP, the

response time is fixed to 250 µs.

SPEED

Response

time

1

500µs

2

2ms

3

8ms

4

32ms

Timer setting

Press the or button to select.

Can be set between 0.1 and 5000 ms.

When *1 is selected, the ON delay timer is

activated.

Timer setting 2

Sets an OFF delay (one-shot) time.

Press the or button to select.

Can be set between 0.1 and 5000 ms.

MODE

MODE

MODE

MODE

MODE

MODE

MODE

6

Setting the shift function

Press the or button to select.

• Do not use shift.

• Use shift.

Output 1/2 common

8

Setting the hysteresis mode

Press the or button to select.

Hysteresis: small

Hysteresis:

large

Output 1/2 common

7

Selecting the control input function

Press the or button to select.

• Does not use the control input

• External calibration

• Bank selection

• Laser emission stop

Output 1/2 common

When OFF

is selected

When

ON is

selected

Setting the shift target value

Press the or button to select.

It can be set by the unit of 1.

MODE

MODE

MODE

MODE

(End Program)

* Output 2 cannot be used when the Area detection mode is selected.

If a mode other than the Normal/Area detection mode is selected for either Output 1 or 2, the

setting of item 5 or 6 cannot be selected for both Output 1 and 2.

Selecting the shift function input time

Press the or button to select.

• 5ms

• 20ms

The input time is fixed to 20 ms for all other functions.

Switching zero datum settings

Press the or button to select.

• Standard

• Hight-accuracy
* When Hi (High-accuracy) is selected, the width for the zero
datum setting value becomes smaller. During this state, be
especially aware of shocks and other causes of fluctuation.

Selecting the memory of value set by an

external input while using the shift function

Press the or button to select.

• Saves the value *1

• Does not save the value (clears data at power-off)
*1 Data can be saved up to one million times.

Selecting the acquisition of the sampling

value* (received light intensity)

Press the or button to select.

• Use the average value from sampling

• Use the peak value from sampling

• Use the bottom value from sampling

* Used during % calibration or display scaling.

MODE

MODE

MODE

MODE

(End Program)

Selecting the Power saving function (Eco mode)

Press the or button to select.

• Normal use

• Eco-half

• Eco-all

Press , , and for three seconds or more at the same time.

MODE

SET