3 minimum input time and output response time – KEYENCE EX-V Series User Manual
Page 106
Advertising

Chapter 6 Specifications and Dimensions
6
96
6.3
Minimum Input Time and Output Response Time
This section describes the minimum input time and the output response time of the
EX-V series.
Minimum input time
The minimum input time required for the TIMING, HOLD RESET, ZERO, OUTPUT
DISABLE and EXT1/EXT2 is as follows:
■ TIMING and HOLD RESET
■ ZERO, OUTPUT DISABLE and EXT1/EXT2
■ SYNC
Note: The minimum input time does not include the processing time after the signal
is received.
ON: 1.5 ms
OFF: 1.5 ms
ON OFF
ON: 15 ms
OFF: 15 ms
ON
OFF
3 ms min.
13 ms min.
2.5 ms
2.5 ms
2 ms
12.5 ms
ON
OFF
ON
OFF
ON
OFF
SYNC input
Measurement
Sensor head oscillation
Advertising