Chapter 4 Use of Data Processing Functions

4

67

■ Flicker mode

•

When the power is turned ON or the hold-reset signal is input, the display
shows "----" until the first measured value is determined.

•

The internal timing signal is input once at every flicker time and the measured
value at the instant is displayed/output.

Average measurement function [b-2]

Calculates the average of the measured values during a specified period (sampling
period).
For the average measurement function, you can select the method to specify the
timing by the combination of the trigger mode and delay time.

➮ For the details of the trigger mode and delay time, refer to pages 69 and 70.

Timing diagram

■ External trigger mode

•

The sampling period is between the UP edge of the hold-reset input and the UP
edge of the next timing input.

•

The value measured at the instant when the timing input turns ON is displayed/
output.

Reference: To start the measurement again, short-circuit the hold-reset and GND
terminals.

(t)

0

ON

OFF

Flicker
time

Displayed value

Internal timing

Intermittent
measurement value

(t)

0

ON

OFF

ON

OFF

When the power is turned ON or the hold-reset signal is input,
the display shows " " until the first timing signal is input.

Displayed value

Hold-reset input

Timing input

Average measurement value