Communication Response Time

Time Frames of Communication Response Time

This section describes the communication time frames (T2 to T6).

The maximum time required is shown for each time frame. However, depending on the
actual environment, it may require more time.

T2 (DL-RS1A data processing time)

For information on the calculation function, refer to the manual supplied with the sensor amplifiers.

When calculation function of sensor amplifiers is OFF

*

* This table also applies to the sensor amplifiers that do not have the calculation function.

When calculation function of sensor amplifiers is ON

T3 (Command send time from external device)

Refer to the manual supplied with the external device connected to DL-RS1A.

Reference

Number of connected

sensor amplifiers

Data processing time (T2)

GT-70A Series

1

7 ms

2

9 ms

3

13 ms

4

15 ms

5

19 ms

6

21 ms

7

25 ms

8

27 ms

9

31 ms

10

33 ms

Number of connected

sensor amplifiers

Data processing time (T2)

GT-70A Series

1

10.5 ms

2

13.5 ms

3

19.5 ms

4

22.5 ms

5

28.5 ms

6

31.5 ms

7

37.5 ms

8

40.5 ms

9

46.5 ms

10

49.5 ms

Communication Response Time

T4 (DL-RS1A command processing time)

The processing time varies according to the command sent from the external device.

Read commands

Write commands

Communication command

Number of connected

sensor amplifiers

Command processing time (T4)

GT-70A Series

SR

1

14 ms

2

15 ms

3

17 ms

4

18 ms

5

20 ms

6

21 ms

7

23 ms

8

24 ms

9

26 ms

10

27 ms

M0/MS/DRQ input

1 to 10

4 ms

Communication command

Number of connected

sensor amplifiers

Command processing time (T4)

GT-70A Series

SW

1

14 ms

2

15 ms

3

17 ms

4

18 ms

5

20 ms

6

21 ms

7

23 ms

8

24 ms

9

26 ms

10

27 ms

AW

1

57.5 ms

2

58.5 ms

3

60.5 ms

4

61.5 ms

5

63.5 ms

6

64.5 ms

7

66.5 ms

8

67.5 ms

9

69.5 ms

10

70.5 ms