Specifications, Performance specifications, Communication specifications – KEYENCE DL-RS1A/GT-70A User Manual

Page 18

Advertising
background image

16

Communication Response Time

T5 (Response send time from DL-RS1A)

The time required to send a response varies depending on the communication speed, data bit
length, and number of bytes.
For information on the communication settings, refer to page 2.
The response time can be calculated using the following formula:

T5 = (number of bytes) x (data bit length + 4) / (communication speed)

Number of bytes for different commands

SR command : (number of bytes in the read data) + 12
M0 command : {(number of bytes in the read data) + 1} u number of connected sensor amplifiers + 4
MS command : {(number of bytes in the read data) + 3} u number of connected sensor amplifiers + 4
DRQ input

: {(number of bytes in the read data) + 3} u number of connected sensor amplifiers + 4

SW command : 11
AW command : 8
* For information on the number of bytes in the write data and the number of bytes in the read data,

refer to "Parameters of Commands and Responses" (page 10).

Sample calculation

T6 (Sensor amplifier settings change time)

For information on the calculation function, refer to the manual supplied with the sensor amplifiers.

When calculation function of sensor amplifiers is OFF

T6 = 0 ms for SW and AW commands; the sensor amplifiers complete modifying their settings during
the T4 period.
* This table also applies to the sensor amplifiers that do not have the calculation function.

When calculation function of sensor amplifiers is ON

SW and AW commands both require the processing time shown below.

Number of bytes

Data length

Communication speed

Response time

21

8 bit

9600 bps

26 ms

114

8 bit

9600 bps

143 ms

21

7 bit

38400 bps

6 ms

114

7 bit

38400 bps

33 ms

Number of connected sensor amplifiers

Settings change time (T6)

1

7 ms

2

9 ms

3

13 ms

4

15 ms

5

19 ms

6

21 ms

7

25 ms

8

27 ms

9

31 ms

10

33 ms

Specifications

Performance Specifications

The following table shows the performance specifications for DL-RS1A.

* The number of connectable sensor amplifiers varies depending on the model to be connected.

• When configured with the GT-70A Series/FD-MA Series units: Up to 10 units (including the master unit)

(When multiple models are included, the maximum number of connectable units is limited to that of the model with

the least number of connectable units.)

Communication Specifications

The following table shows the communication specifications for DL-RS1A.

Item

Specifications

Model

DL-RS1A

Power supply voltage

20 to 30 VDC, including 10% ripple (P-P). Class2

(Supplied from the connected sensor amplifier)

Current consumption

25 mA max.

Number of connectable

sensor amplifiers

Varies depending on the model*

Indicators

2 communication status indicators (green), alarm indicator (red), power indicator

(green)

Environ-

mental

Ambient

temperature

-10 to +55°C (No freezing)

Relative

humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of XYZ axes

Material

Main unit housing: polycarbonate

Weight

Approx. 53 g

Accessories

Instruction manual, 2 end units, expansion connector cover, switch protection

sticker

Item

Specifications

Communication method

Full duplex

Synchronization method

Asynchronous

Transmission code

ASCII

Communication speed

(Baud rate)

2400, 4800, 9600, 19200, 38400 bit/s

(Factory default: 9600 bit/s)

Data bit length

7 or 8 bits (Factory default: 8 bits)

Parity check

None, even, odd (Factory default: none)

Stop bit length

1 bit

Data delimiter

Receive: automatically detect CR or CR + LF

Send: fixed to CR + LF

Advertising