Function setting mode, Basic setting mode – KEYENCE GT2 Series User Manual

Page 2

Advertising
background image

2

Changing the bank (program)

1. Press the up/down arrow button while pressing the MODE button.


2. The bank (program) would be switched to another one. Each bank

(program) will have an own HH/HIGH/LOW/LL/PRESET setting
value.

Function setting mode

How to enter the Function setting mode

1. Press the MODE button for at least 2 seconds.


2. Press the left/right arrow button and select the function number.

01 Detection mode

Set the detection mode from [Standard], [NG hold], [Peal hold], [Bottom

hold] or [Peak to peak] mode.

02 Hold update method

Set how to update the hold value from [Timing input] or [Regular
update].
Only available when

is set to [Standard], [Peal hold] or

[Bottom hold].

03 Response time

Set the response speed.

04 Timing type

Set the timing time from [External input], [Rising edge] or [Falling edge].
Only available when

is set to [Standard], [Peal hold] or

[Bottom hold].

05 Self timing level

Set the self timing level. Only available when

is set to

[External input].

06 Self timing delay type

Set how the value is decided after the self timing is input, from [Static
hold] or [Delay timer].
Only available when

is set to [Standard], and

is set

to [External input].

07 User specified delay time

Set the delay time used for

.

Only available when

is set to [Delay timer].

08 Static hold delay stability criterion

Set how the decide the range, which is used to judge if the value is
stable or not, from [Default] or [User].

Only available when

is set to [Static hold].

09 Static hold delay stability width

Set the range which is used to judge if the value is stable or not.
Only available when

is set to [User].

Basic setting mode

How to enter the Function setting mode

1. Press the MODE and SET button at the same time for at least 2

seconds.


2. Press the left/right arrow button and select the function number.

10 Measurement direction change

Set how the value moves, when the spindle is pressed, from [Normal]
or [Reverse].

11 Measurement direction change

Set a number if the value has to be multiplied.

12 Output format

Set the output mode from [N.O.] or [N.C.].

[MODE] button

Main screen

[MODE]

button

[SET] button

Main screen

While holding

down [MODE],
press the [Up].

While holding down

[MODE], press [Up].

While holding down

[MODE], press [Up].

While holding down

[MODE], press [Up].

<Bank 0 is selected>

<Bank 1 is selected>

<Bank 2 is selected>

<Bank 3 is selected>

The bank indicator is

turned off.

The bank indicator 1

is lit in green.

The bank indicator 2

is lit in green.

The bank indicator 3

is lit in green.