1. Safety Precautions

WARNING

Do not use this product in safety circuits such as those designed to

protect human workers.

This product does not employ an explosion-proof construction. Do

not use it in the presence of flammable gasses, liquids, or powders.

This is a direct current power supply type sensor. Application of an

alternating current may result in explosion or fire.

Accessories

3. Pipe Connections

You can select from one of two pressure ports: one on the back of the

sensor that can accommodate a pipe leading directly away from the back

of the sensor, and one on the side of the sensor to accommodate a pipe

leading away from the sensor at a right angle.

1) The pressure port is 1/8 of Rc (PT). Commercially available air pres-

sure joints and nipples can be used with the port.

When attaching the joint, use a wrench to hold the pressure port in

place as illustrated below.

Hold in place

with wrench

(12mm).

2) Attach the included valve plug to the pressure port not being used.

Hold in place with

wrench (12 mm).

Hexagonal

wrench (5mm)

Valve plug with

hexagonal hole

CAUTION

• Do not use a torque in excess of 10 Nm when tightening the joint.

Doing so may damage the joint.

• Apply sealing tape when attaching the joint in order to prevent air leaks.

4. Mounting Brackets (option)

Dedicated mounting hardware is available for the sensor, allowing it to

be installed in a range of locations.

Horizontal mounting bracket

Wall mounting bracket

(AP-BO1)

(AP-BO2)

Faceplate/ceiling mounting bracket

Tilted mounting bracket

(AP-BO3)

(AP-BO4)

Substitution bracket

(AP-BO5)

1 connector cable (2 m)

1 unit scale label

(AP-C33 only)

2. Part Names

SET

AP-C33

MODE

MPa

2

1

Pressure display unit

Pressure display

Mode button

Manual adjustment button
Set button

Wiring
connector

Pressure
port (rear)

Pressure port
(side)

Mounting screws
(M3 x 2)

Operational indicator

Output 1

Output 2

1

2

Approx. 90

1 valve plug with hexagonal hole

1 instruction

manual

96M1312

1.

Safety Precautions

2.

Part Names

3.

Pipe Connections

4.

Mounting Brackets (option)

5.

Connection Method and Diagrams

6.

Precautions for Safe Use

7.

Detection Mode Operation

8.

Sensor Configuration

9.

Explanation of Features

10.

Active Tuning

11.

Default Mode Settings (Initialization)

12.

Specifications

13.

Ambient Pressure Compensation

14.

Key Lock

15.

Error Displays and Corrective Actions