Sensor configuration – KEYENCE AP-C30(P) Series User Manual

Page 3

Advertising
background image

3

After 4 sec

of no key

operation.

Reference value*

Press for 3 sec or more.

+

+

Increase the

setting.
Decrease the

setting.

Operating mode

Standard
Focus mode

AP-C30/C

35

AP-C31/

C31P/C33

/C33P

When

operating

mode is

• Two-point tuning
• Active tuning

Display color (7-segment)

ON: Red, OFF: Green
ON: Green, OFF: Red
Normally red
Normally green

Within set value: Green

Outside set value: Red

Detection range (AP-C30/C35)

Positive pressure range

Compound pressure range

Negative pressure range

Focus center pressure

■

Toggling the

display

■

Manual configuration

Settings are

manually

configured. The

display changes

for each mode.

* Toggling the

display of

settings (see the

diagram below).

* Manual

configuration

only during F-3/A-

2 mode operation.

Current value

Peak hold

Bottom hold

* The reference value is

the pressure value when

zero shift input is

received and is replaced

only when zero shift

input is selected.

■

Mode

configuration

Current value

Reference value

Hold value

Detection mode

General-purpose mode
Variable hysteresis mode
Window mode
Application mode 1
Application mode 2

Zero shift input
Analog output

N.O./N.C.

N.O.
N.O.
N.C.
N.C.

N.O.
N.C.

N.C.

N.O.

Control

output 1

Control

output 2

2.5 msec
5

msec

100 msec
500 msec

Analog/zero shift

Chatter prevention

Sets response time.

• N.O.

= normal open.

• N.C.

= normal close.

Standard
Eco mode

Power-save

* See the Focus Mode section

of Part 9 for the center

pressures that can be

selected.

* F-1 and F-2 mode only

Values that fall between the P1

and P2 settings will be

displayed in green, while values

outside that range will be

displayed in red.

*

When

A-1/A-2 is

selected

The display color

is independent of

the control output.

The conditions of

ON/OFF in the

right table is the

case when N.O.

is set.

during

fixed mode

operation

(

)

8. Sensor Configuration

■

Toggling the display of settings

●

General-purpose mode/F1

●

Variable hysteresis mode/F-2

●

Window mode/F-3

●

Application mode 1/A-1

●

Application mode 2/A-2

■

Two-point tuning (F-1/F-2)

The sensor is made to detect the pressures when the target object is

present and then absent for confirmation of target suction pick-up, and

the intermediate value is used.

Control output 1 configuration: When P1 (H1) is selected on the settings

display.

Control output 2 configuration: When P2 (H2) is selected on the settings

display.

Flashes

for 3 sec.

Setting

Target object

present

Target object

absent

■

Active tuning (A-1)

See Section 10.

Note: • Press and hold the MODE button ( ) for at least 3 seconds to return to the current

value/reference value/hold value display from each of the mode setting screens.

• Press the left side

on the manual adjustment button (

) while holding down the

mode button ( ) to return to the previous display.

• The current value will be displayed based on the ambient pressure conditions prevalent

at that time without regard to zero shift input when the P2 setting display is selected for
A-1 mode or when the Hi and Lo setting displays are selected for A-2 mode.

• The sensor must be configured manually when operating in the F-3/A-2 modes. The

SET button ( ) will not function.