Connection method and diagrams, Precautions for safe use, Detection mode operation – KEYENCE AP-C30(P) Series User Manual

Page 2: Ap-ao1 panel mounting bracket, Caution, Analog output circuit

Advertising
background image

2

AP-AO1 Panel mounting bracket

SET

AP-C33

MODE

MP

a

SET

AP-C40

MODE

MP

a

Panel mounting ring

Panel-mounted sample

Front protective

cover

Panel-mounted sample

5. Connection Method and Diagrams

Insert the included connector-tipped cable into the sensor’s connector.

Position the connector so that the side of the connector where the metal-

lic contacts are visible is facing up.

Connector cable

Side where the metallic

contacts are visible faces up.

Input/output circuit

(AP-C30/C31/C33/C35)

(AP-C31P/C33P)

12 to 24 VDC

5 to 40 VDC

5 to 40 VDC

0V

Main cir

cuit

Ov
er

curr
ent

pr

ot

ection cir

cuit

Load

Load

Input/output

circuit

Analog output/

zero shift input: switchable

Brown

Blue

Black

White

Pink

12 to 24 VDC

0V

Main cir

cuit

Ov

er

curr
ent

pr

ot

ection cir

cuit

Input/output

circuit

Analog output/

zero shift input: switchable

Brown

Blue

Black

White

Pink

Load

Load

Analog output circuit

Analog

output (1 to 5 V)

0 V

Main

cir
cuit

Blue

Pink

Zero shift input circuit (NPN)

Zero shift input circuit (PNP)

(Short-circuit current 5 mA max.)

Main

cir
cuit

Blue

Pink

12 to 24 VDC

Main

cir
cuit

Pink

(Short-circuit current 5 mA max.)

Brown

Use non-contact input device such as open-collector.

6. Precautions for Safe Use

Follow these guidelines. Failure to do so may result in product damage.

CAUTION

■

Connections

Input/output circuit

●

Always ground the frame ground terminal when using an off-the-

shelf switching regulator.

●

Use separate conduits for power line and high voltage lines, since

use of a common conduit may result in device malfunction.

●

Improper wiring may result in the device becoming excessively hot

or in device damage.

■

Other

●

Do not use this sensor with corrosive gasses or liquids.

●

Do not insert objects such as wire into the pressure insertion area.

Doing so may result in the device failing to operate properly due to
damage to the pressure-sensitive elements.

●

Do not use sharp-tipped objects to press the setting keys.

7. Detection Mode Operation

■

General-purpose mode (F-1)

This mode allows the user to configure 2 detection points.

Control output 1: Turns ON when pressure exceeds setting P1.

Control output 2: Turns ON when pressure exceeds setting P2.

<Output 1>

P1

0

Output 1 OFF

ON

OFF

P2

0

OFF

ON

OFF

<Output 2>

Output 2

* Hysteresis is a standard 0.5% of F.S. when operating in general-purpose

mode and application modes 1 and 2. During focus mode operation, it is

0.2% of F.S.

■

Variable hysteresis mode (F-2)

Two detection points may be user-configured, and hysteresis for both

may also be set.

Control output 1: Turns ON when pressure exceeds setting P1. Turns OFF

when pressure drops the selected hysteresis amount

below P1.

Control output 2: Turns ON when pressure exceeds setting P2. Turns OFF

when pressure drops the selected hysteresis amount

below P2.

<Output 1>

P1

H1

Output 1

OFF

ON

OFF

0

P2

OFF

ON

OFF

H2

0

<Output 2>

Output 2

■

Window mode (F-3)

The user may select a pair of upper (Hi) and lower (Lo) thresholds,

and the sensor turns OFF when the pressure falls outside of the result-

ing range.

* Control output 1 is a standard 0.5% of F.S. During focus mode opera-

tion, it has a hysteresis of 0.2% of F.S., and control output 2 has a

hysteresis of 0.

Hi

Lo

Output1/Output2 OFF ON

ON

OFF

OFF

<Output 1/Output 2>

0

■

Application mode 1 (A-1)

This detection mode is optimum for use in suction detection applica-

tions.

Recommended sensor heads: AP-C30/C31/C31P

Control output 1: Suction pressure detection.

Turns ON when pressure exceeds setting P1.

Control output 2: Detection and confirmation of vacuum burst pressure

detection (or vacuum ultimate pressure).

Turns ON when the pressure falls below setting P2.

* Cannot be used to detect vacuum burst pressure with

the AP-C31/C31P when operating in focus mode.

Standard mode operation only.

Zero shift:

The zero point is shifted immediately after the zero

shift timer is set following the activation of zero shift

input.

P1: Pressure setting for control output 1.

T1: Zero shift timer setting (ms) < Variable between 0 and 1,999 ms

P2: Pressure setting for control output 2.

* P2 is unrelated to zero shift and is always based on the current ambi-

ent pressure.

■

Application mode 2 (A-2)

This mode is optimum for use in leak test applications.

Recommended sensor head: AP-C33/C33P

Control output 1: Leak pressure detection.

Turns ON when pressure falls below setting P1.

*Output only when receiving zero shift input.

Control output 2: Window comparator output for detection of fill pressure.

Turns OFF when pressure falls outside the range deter-

mined by upper (Hi) and lower (Lo) thresholds.

* Fill pressure values are displayed with the center pres-

sure as 0 during focus mode operation.

P1: Pressure setting for control output 1.

Hi: Upper threshold setting for control output 2.

Lo: Lower threshold setting for control output 2.

* The Hi and Lo values are unrelated to zero shift and are always based

on the current ambient pressure.

<Output 1>

P1

Output 1 OFF

ON

OFF

0

<Output 2>

0

Output 2 OFF

ON

OFF

P2

0

0

Shift

Zero shift input

T1

<Zero shift>

<Output 1>

P1

Output1

Zero shift input

OFF

ON

OFF

ON

0

<Output 2>

Hi

Lo

Output 2 OFF

ON

OFF

OFF

ON