IV Series (Sensor) - IM_E

Specifications

Model

IV-500C

IV-500CA IV-500M IV-500MA

IV-150M

IV-150MA IV-2000M IV-2000MA

Installed distance

Standard distance (50 to 500 mm)

Short range (50 to 150 mm) Long range (300 to 2000 mm)

View

Installed distance 50 mm : 25 (H) x 18 (V) mm

to

Installed distance 500 mm : 210 (H) x 157 (V) mm

Installed distance 50 mm :

12 (H) x 9 (V) mm

to

Installed distance 150 mm :

36 (H) x 27 (V) mm

Installed distance 300 mm :

45 (H) x 33 (V) mm

to

Installed distance 2000 mm :

300 (H) x 225 (V) mm

Image sensor

1/3 inch color CMOS 1/3 inch monochrome CMOS

Pixel

752 (H) x 480 (V)

Focus adjustment

Manual

Auto

*1

Manual

Auto

*1

Manual

Auto

*1

Manual

Auto

*1

Exposure time

1/10 to 1/50,000

1/10 to 1/25,000

1/20 to 1/25,000

1/10 to 1/25,000

Lights

Amplifier type White LED

Red LED

Infrared LED

Lighting method Pulse lighting/DC lighting is switchable

Tools

Type

Outline search, Color area

*7

, Area

*8

, Position adjustment

Number

*2

Detection tools : 16 tools, Position adjustment tool : 1 tool

Switch settings (programs) 32 programs

Image

history

*3

Numbers

100 images

*4

300 images

*5

Condition

NG only/All is selectable

Analysis information

*6

OFF/Statistics/Histograms is switchable

Statistics : Processing time (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs,

trigger numbers, trigger errors, judge results list by tools

Histograms : Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs

Other functions

HDR, HighGain, Color filters

*7

, Digital zoom

*8

, Brightness correction, Tilt correction, White balance

*7

,

Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator

*9

Indicators

PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

Input

No-voltage input/voltage input is switchable

For no-voltage input : ON voltage 2V or lower, OFF current 0.1mA or lower, ON current 2mA (short circuit)

For voltage input : Maximum input rating 26.4V, ON voltage 15V or higher, OFF current 0.2mA or

lower, ON current 2mA (for 24V)

Inputs

6 inputs (IN1 to IN6)

Function

IN1 : External trigger, IN2 to IN6 : Enable by assigning the optional functions

Assignable functions : Program switching, Clear error, External master image registration

Output

Open collector output NPN/PNP is switchable, N.O./N.C. is switchable

For open collector NPN output : Maximum rating 26.4V 50mA, remaining voltage 1.5V or lower

For open collector PNP output : Maximum rating 26.4V 50mA, remaining voltage 2V or lower

Outputs

4 outputs (OUT1 to OUT4)

Function

Enable by assigning the optional functions

Assignable functions : Total judge result, RUN, BUSY, Error, Position adjustment result, Judge

result of each tool, Result of the logical operation of each tool

Ethernet

*10

Standard

100BASE-TX/10BASE-T

Connector

M12 4pin connector

Network function

FTP client, EtherNet/IP, PROFINET

Rating

Power voltage DC 24V ± 10% (including ripple)

Consumption

current

0.6 A or less

Environmental

resistance

Ambient

temperature 0 to +50°C (No freezing)

Relative humidity 35 to 85%RH (No condensation)

Vibration

10 to 55 Hz, 1.5 mm double amplitude, 2 hours each for X, Y, and Z axes

Shock resistance 500m/s

2

6 different directions in 3 times

Enclosure rating

*11

IP67

Material

Main unit case : Aluminum die-casting, Packing : NBR, Front Cover : Acrylic, Mounting adapter : POM

Weight

Approx. 270 g

*1 The focusing position can be automatically adjusted at the time of installation. Deactivated during the operation. The focusing

position can be registered by programs.

*2 Tools can be installed by programs.

*3 Saves to the memory in the sensor.

The images saved in the sensor can be backed up to the USB memory installed to the intelligent monitor (IV-M30) or to the

PC by the software for IV (IV-H1).

*4 When using the FTP client function ; 70 pictures

*5 When using the FTP client function ; 210 pictures

*6 This can be displayed on the intelligent monitor (IV-M30) or by the software for IV (IV-H1).

*7 Color type only.

*8 Monochrome type only.

*9 This function can be used with the software for IV (IV-H1).

*10 This is for connection with the intelligent monitor (IV-M30) or the software for IV (IV-H1).

*11 Except when polarized filter attachment (OP-87436/OP-87437) is mounted.