4 connecting the bl-n70rke, Connecting the bl-n70rke -6, Connecting the bl-n70rke – KEYENCE BL-N70 Series User Manual

Page 20: Z communication settings

Advertising
background image

2-6

2

Conne

ct

ion
s

2-4

Connecting the BL-N70RKE

BL-N70RKE can be connected to the AutoID data controller DV-90 and to the dedicated

communication units BL-U1, BL-U2, and N-42. These components have a regulated 5VDC

power supply on Pin 9 of the D-sub connector.

‹

Connector pins for BL-N70RKE

z Communication Settings

The following values represent factory settings for the BL-N70RKE. The settings can be

changed (

page 4-22). Make sure that the settings for BL-N70RKE and the connected

equipment are the same.

• Baud rate

: 9600 bit/s

• Data length

: 7 bits

• Parity

: Even

• Stop bit

: 1 bits

• Communication protocol : No protocol

CAUTION

Although it may be possible to connect the BL-N70RKE to external power
supplies, it is not recommended. Applying more than 5VDC +/-5% may
damage the scanner.

BL-N70RKE

To Keyence

products

(D-sub 9-pin)

Pin No.

Symbol

Description

Signal direction

2

RD (RXD)

Receives data

Input

3

SD (TXD)

Sends data

Output

4

-

Does not make any connection

-

5

SG

Signal ground

-

6

-

Does not make any connection

-

7

RS (RTS)

Request to send data

Output

8

CS (CTS)

Ready to send data

Input

9

Vcc

Inputs +5V DC power supply

Input

D-sub 9-pin (female)

#4-40 screws

Advertising