CHAPTER 1: SAFETY PRECAUTIONS

PR2: 05/09/12 Page

9 of 162

Benchmark 1.5LN Dual-Fuel Low NOx Boiler

Operation and Maintenance Manual

OMM-0041_0C

GF-121

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913 • Ph: 800-526-0288

CHAPTER 1: SAFETY PRECAUTIONS

1.1 WARNINGS & CAUTIONS

Installers and operating personnel MUST, at all times, observe all safety regulations. The

following warnings and cautions are general and must be given the same attention as specific

precautions included in these instructions. In addition to all the requirements included in this

AERCO Instruction Manual, the installation of units MUST conform with local building codes, or,

in the absence of local codes, ANSI Z223.1 (National Fuel Gas Code Publication No. NFPA-54).

Where ASME CSD-1 is required by local jurisdiction, the installation must conform to CSD-1.

Where applicable, the equipment shall be installed in accordance with the current Installation

Code for Gas Burning Appliances and Equipment, CSA B149.1, and applicable Provincial

regulations for the class; which should be carefully followed in all cases. Authorities having

jurisdiction should be consulted before installations are made.

IMPORTANT

This Instruction Manual is an integral part of the product and must

be maintained in legible condition. It must be given to the user by

the installer and kept in a safe place for future reference.

WARNING

MUST BE OBSERVED TO PREVENT SERIOUS INJURY

.

WARNING

BEFORE ATTEMPTING TO PER-FORM ANY MAINTENANCE

ON THE UNIT, SHUT OFF ALL GAS AND ELECTRICAL INPUTS

TO THE UNIT.

WARNING

THE EXHAUST VENT PIPE OF THE UNIT OPERATES UNDER

A POSITIVE PRESSURE AND THERE-FORE MUST BE

COMPLETELY SEALED TO PREVENT LEAKAGE OF

COMBUSTION PRODUCTS INTO LIVING SPACES.

WARNING

A DOUBLE-POLE SWITCH MUST BE INSTALLED ON THE

ELECTRICAL SUPPLY LINE OF THE UNIT. THE SWITCH MUST

BE INSTALLED IN AN EASILY ACCESSIBLE POSITION TO

QUICKLY AND SAFELY DISCONNECT ELECTRICAL SERVICE.

DO NOT AFFIX SWITCH TO UNIT SHEET METAL

ENCLOSURES.

WARNING

DO NOT USE MATCHES, CANDLES, FLAMES, OR OTHER

SOURCES OF IGNITION TO CHECK FOR GAS LEAKS.

WARNING

FLUIDS UNDER PRESSURE MAY CAUSE INJURY TO

PERSONNEL OR DAMAGE TO EQUIPMENT WHEN

RELEASED. BE SURE TO SHUT OFF ALL INCOMING AND

OUTGOING WATER SHUTOFF VALVES. CAREFULLY

DECREASE ALL TRAPPED PRESSURES TO ZERO BEFORE

PERFORMING MAINTENANCE.