CAMCORP HVP with Duroflow Blower User Manual

Page 13

Advertising
background image

CAMCORP, INC.

Phone: 913-831-0740 Fax: 913-831-9271

Platform Installation: The platform, ladder, handrail, and bracing are to be installed as
shown on the special platform detail provided. Use the part ID’s to locate the parts in the
proper location.

Explosion Vents (where applicable):

1. Figure 6 – The explosion vents are attached with a minimum of standard

steel fasteners for shipment. THESE MUST BE REMOVED and the
PVC Bolts installed that are included in the shipment. Extreme care should
be exercised when installing the PVC Bolts as they are very fragile. A
gasket is factory installed that will provide a seal between the vent panel
and the frame. DO NOT use silicone sealer or any other sealer or adhesive
at this joint as this will prevent the vent from operating properly.

2. The area around the vents should be clear of any personnel or obstructions

to prevent injury or damage.

5-2

Advertising