D--9--610 Page 14

SECTION 4

OPERATION

Future operating problems can be avoided if proper

precautions are observed when the equipment is first

put into service.

Before starting under power, the blower should be

turned over by hand to make certain there is no binding,

or internal contact.

LIMITATIONS

Each size blower has limits on pressure differential,

running speed, and discharge temperature which must

not be exceeded.

These limits are shown in

FIGURE 4--1, page 15.

Operating beyond the specified oper-

ating limitations will result in damage

to the unit.

To accurately determine actual blower operating condi-

tions, it is important that all pressure and temperature

recordings are made directly at the ports of the blower

where these conditions are at their maximum.

Relief valves MUST be used to protect the blower

against excessive pressure or vacuum conditions.

These valves should be tested at initial start up to be

sure they are adjusted to relieve at 2 psi above the

maximum allowable pressure or at 2” HG below the

maximum allowable vacuum for the blower. Periodic

testing of relief valves is suggested to assure that they

are functioning.

Relief valves should be placed as

close as possible to the blower inlet

on vacuum systems or discharge on

pressure systems.

Check valves must be installed on the discharge side

of the blower on a pressure system and on the inlet side

of the blower on a vacuum system to eliminate product

ingestion resulting from autorotation and blow back

during equipment shutdown.

SAFETY PRECAUTIONS

1.

Do not operate the blower with an open inlet or

discharge port.

2.

Do not exceed specified vacuum or pressure

limitations.

3.

Do not operate above or below recommended

blower speed range.

4.

The blower is not to be used where non--sparking

equipment is specified. Contact your DuroFlow

Distributor for non--sparking requirements.

5.

Do not operate the blower without belt guard or

coupling shield properly installed.

6.

Do not exceed the manufacturer’s specified rim

speed limit for sheaves or couplings.

7.

The blower and blower discharge piping may be

extremely hot and can cause skin burns on

contact.

8.

Do not exceed the manufacturer’s certification

levels for vacuum or pressure vessels.

Advertising