5-4

CAMCORP, INC.

Phone: 913-831-0740 Fax: 913-831-9271

Gauges: Check the pressure differential gauge to make sure that the high-pressure tap is
connected below the tube sheet and the low-pressure tap is connected above the tube
sheet. Verify that the gauge have been zeroed prior to connection when it is in its
permanent mounting position.

Cleaning Air PD Pump: The PD Pump must be install at the base of the filter to
accommodate installation of the Air Supply line. Securely anchor in permanent location.
Required line size as follows:

Air Supply

Model:

Pipe Diameter

HVP48 thru 112

1”

HVP 152 thru 256

1-1/2”

HVP 312 thru 504

2”

Auxiliary Equipment: All auxiliary equipment must be installed according to its
manufacturer’s specifications and interlocked with the entire system as needed. Direction
of rotation of each item must be checked prior to start-up of the entire system.