TROUBLESHOOTING THE CLEANING MECHANISM

1. Diaphragm Valve – Pulsing Failure. The Diaphragm assembly consists of (3)

components. The main diaphragm valve, the secondary diaphragm valve, and the
solenoid valve. Troubleshooting recommendations as follows:

A. Main Diaphragm and Secondary Diaphragm:

1. Diaphragm Valve Bleeding Air – Disassemble and inspect both

diaphragms for ruptured valves or air bleed holes are restricted.
(Reference attached manual) Replace with a repair kit if necessary.

2. Verify Positive Displacement Pump is operating correctly and producing

compressed air.

3. Verify weighted relief valve is weighted correctly allowing tank to build

7-8 PSI pressure.

B. Solenoid Valve:

1. Open or short circuit in wiring between timer and solenoid – Check

continuity with ohmmeter or suitable tester and repair as required.

2. Plastic plug in solenoid exhaust port - Remove and discard plug.

2. Timer – Not Operating

A. Check for mechanical damage.

B. Check the wiring from the timer to the solenoids for open or short circuits.

C. Replace Timer.