CAMCORP HVP with Duroflow Blower User Manual

Page 28

Advertising
background image

CAMCORP, INC.

Phone: 913-831-0740 Fax: 913-831-9271

Symptom

Possible Causes

Possible Sources

Poor Performance

Restricted Inlet

Clogged Filter Element
Collapsed Inlet Hose

Erroneous Pressure

Loose Gauge Connection
Gauge Movement Damaged
Gauge Inaccurately Calibrated

Air Leakage

Improper Relief Valve Setting
Blown Gaskets
Loose Piping Joints

Insufficient Rotor
Speed

Wrong Sheave Set
Wrong Motor Speed
Slipping Belts

Excessive Rotor
Clearances

Abrasive Wear of Rotor
Surfaces
Rotor “Lag” Timed

Leaking Oil

Failed Oil Seals

Foreign Material in Seal Bores
Faulty Installation
Non-spec Oil
Contaminated Oil
Overheated Rotor Shafts

End Cover Seams Not
Tight

Bolts Loose
Gaskets Torn

Oil Foaming

Non-spec Oil
Oil Cavities Overfilled

Chronic Fuse
Blowing or Circuit
Breaking

Excessive Motor
Amperage

Excessive Pump Speed
Line Voltage Drop
Air Density Increase
Loose Electrical Connections
Foreign Material in Air Box

Underrated Fuses

Premature Heater Strip
Actuation

Unusually High Ambient
Temperature
Underrated Heater Strips

11-3

Advertising