3. Positive Displacement (PD) Pump - Following is a list of possible Symptoms and

Troubleshooting Solutions.

Symptom

Possible Causes

Possible Sources

Noisiness

Rotor-to-Rotor
Contact

Rust Build up or Rotors
Rotors Out of Time
Excessive Pressure Ratio
Failed Bearings (s)
Failed Gears

Failing Bearing (s)

Faulty Installation
Non-spec Oil
Contaminated Oil
Insufficient Oil
Improperly Mounted Sheave
Over-tightened Belts

Failing Gears

Insufficient Backlash
Non-spec Oil
Contaminated Oil
Insufficient Oil
Sever Torsional Vibration

Failing Lubricated
Coupling or Joint

Non-spec Grease
Contaminated Grease
Insufficient Grease

Loose Attached
Hardware

Belt Guard
Pump Mounting Bracket
Frame Members
In/Out Piping Supports

Air Leakage

Improper Relief Valve Setting
Blown Gaskets
Loose Piping Joints

Belt Flutter

Insufficient Static Tension
Sheave Misalignment
Sever Torsional Vibration

11-2