ROUTINE MAINTENANCE

A. Inspection

Frequency will vary as widely as there are operating conditions. In general
proceed as follows:

1. Daily – Check unit differential pressure.

2. Weekly – Verify that the pulse arm drive and PD Pump are operating

properly.

3. Monthly – Lubricate fan, rotary valve and screw conveyor. Check seals on

latter two for dust loss.

4. Quarterly – On Top Access Units, check for dust accumulation in clean air

plenum.

B. Repairs

1. Filter bags – Generally replacement, although some applications can be

laundered.

2. Rotary Valves – Usually a matter of periodic seal and blade replacement.

More detailed information is supplied with the valve.

3. Screw Conveyors – Periodic replacement of “V” belts and shaft seals.

Inspect hanger bearings during filter bag change. Failure will be detected by
the squeal.

4. PD Pump – “V” belt tension if running rough. Make sure rotor balance is

maintained.