Symptom

Possible Causes

Possible Sources

Overheating

Excessive Pressure
Ratio

Clogged Filter Element
Collapsed Inlet Hose
Clogged Dust Vent Filter
Undersized Dust Vent Filter
Clogged Diffusion Pads

Insufficient Rotor
Speed

Wrong Sheave Set
Wrong Motor Speed
Slipping Belts

4. Pulse Arm Drive – Motor not rotating.

A. Remove the motor from the gear drive and check for proper operation. If

the motor does not rotate, repair or replace.

B. If the motor does rotate properly check for binding or roughness in the

gear drive. Repair or replace one or both gear boxes as necessary.

5. Pulse Arm Drive – Motor rotating and sweep arm not rotating or rotating

intermittently.

A. Enter the clean air plenum and check for obstructions in the path of the

rotating pulse arm. Remove any obstructions

B. Verify that the pulse arm is rotating parallel to the tubesheet and that the

nozzles do not strike the cage tops and cause the sweep arm to stop. If this
is not the case call the factory.

C. Verify that the torque-limiting clutch on the small sprocket is slipping.

D. Verify that the chain is not binding. If it is then check the sprocket

alignment.

E. Disconnect the drive chain. The pulse arm should rotate freely and with no

binding or roughness. If binding is experienced grease the rotary union. If
the binding or roughness continues inspect the bearing and replace if
necessary.