OPERATION PRINCIPLE

A. Solids laden air or gases enter the unit at the hopper or housing inlet.

B. Air passes through the filter media.

C. Solids are retained on the filter media surface.

D. Cleaning consists of a rotating pulse arm with nozzles positioned over the bags

that randomly pulses 7-8” PSI air into the bags that reverses the airflow.

1. This momentarily takes a row of bags off stream through pressure reversal.

2. Flexing filter bags.

3. Solids are released to fall towards hopper and through rotary valve or other

discharge equipment.