CAMCORP HVP with Duroflow Blower User Manual

Page 68

Advertising
background image

D--9--610 Page 13

Blower

Ambient Temperature

Discharge

Temperature

Less than10_ F *

10_ F to 32_ F **

32_ F to 90_ F

Greater than 90_ F

Less than 32_ F

ISO 100 }

ISO 100 }

(0_ C)

32_ F to 100_ F

ISO 100 }

ISO 100 }

ISO 150 }

(0_ C to 38_ C)

100_ F to 225_ F

ISO 100 }

ISO 100 }

ISO 150 }

ISO 220 }

(38_ C to 105_ C)

225_ F to 300_ F

ISO 150 }

ISO 150 }

ISO 220 }

ISO 220 }

(105_ C to 149_ C)

Greater than 300_ F

*** }

*** }

(149_ C)

*

For ambient temperatures less than 10_ F, but not less than --20_ F, the use of oil sump heaters,

heated enclosures or synthetic lubricant is required.

**

For ambient temperatures 10_ F to 32_ F, the use of oil sump heaters, heated enclosures or

synthetic lubricant is recommended.

***

The lubricant viscosity must be 70 SUS minimum at the lubricant operating temperature.
The pour point of the lubricant should be at least 5_ to 10_ F below the minimum expected ambient

temperature.
For continuous operation, where the lubricant temperature exceeds 200_ F, synthetic lubricant

is recommended.

}

The recommended operating range for AEON PD Synthetic Lubricant.

FIGURE 3--4 -- VISCOSITY RECOMMENDATION