5 "rapid cooling" function enabling/disabling – EVCO EVB1256N9 User Manual

Page 25

Advertising
background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.2 | Code 144BOX1E124

page 25 of 88

The following table shows the correspondence between the

labels and the magnitudes displayed.

LABEL

MAGNITUDE

Pb1

room/inflowing air temperature; see also

parameter P4

Pb2

evaporator temperature

Pb3

auxiliary temperature; see also parameter P4

Pb4

CPT temperature; see also parameter P4

Pb5

if present, vapour pressure

Pb6

if present, evaporation temperature

4.

Press and release the key “SET”.

To exit the procedure:

5.

Press and release the key “SET” or do not operate

for 60 sec.

6.

Press and release the “UP” or “DOWN” key until

the display shows the magnitude established with

parameter P5 or do not operate for 60 sec.

Alternatively:

7.

Press and release the “ON/STAND-BY” key.

If the evaporator temperature sensor is not present (or if the

P3 parameter is set to 0), the "Pb2" label shall not be

displayed.

If the auxiliary temperature sensor is not present (or if the P4

parameter is set to 0), the "Pb3" label shall not be displayed.

If the magnitude recorded by the auxiliary sensor is not the

outgoing air temperature (or if the P4 parameter is not set to

4) the "Pb4" label shall not be displayed.

6.5

"Rapid cooling" function

enabling/disabling

To enable/disable the "rapid cooling" function, proceed as

follows:

1.

Check that the device is turned on, that the

keypad is not locked, that no procedures are in

progress and that there are no defrosting, dripping

or evaporator fan stop operations in progress.

2.

Keep the "UP" key pressed for 4 s: the

"temperature" LED light shall start flashing.

Displaying the magnitude detected by an analogue input

"Rapid cooling" function enabling/disabling