During the "rapid cooling" function the work set point is

decreased by the temperature set with the r5 parameter; the

function runs for the span of time set with the r6 parameter.

During the "rapid cooling" function the defrosting function is

never activated; if the defrosting interval expires while the

rapid cooling function is in progress, the defrosting shall be

activated at the end of the cooling.

6.6

Defrosting manual activation

To activate the defrosting in manual mode, proceed as follows:

1.

Check that the device is turned on, that the

keypad is not locked, that no procedures are in

progress and that the "rapid cooling" function is

not in progress.

2.

Keep the "DEFROSTING" key pressed for 4 s.

If the evaporator temperature sensor functions as a defrosting

sensor (that is to say,if the P3 parameter is set to 1) and when

the defrosting starts the evaporator temperature exceeds the

value set with the d2 parameter, the defrosting shall not be

activated.

6.7

Turning on/off of room lights

manually (only if the parameter

u1 and/or parameter u11 is set at

0)

To turn the room light on/off in manual mode, proceed as

follows:

1.

Make sure no procedures are in progress.

2.

Press and release the "AUXILIARY" key: the "room

light" LED shall turn on/off.

Through the digital ports it is also possible to turn the room

light on/off from remote; see parameter u2.

If parameter u1 and/or parameter u11 are set to 2 (that is to

say, if the application managed by the K5 and/or K6 outputs is

the auxiliary output), pressing the "AUXILIARY" key for 2 s

shall make the "auxiliary 1" and/or "auxiliary 2" and the

auxiliary output LEDs turn on/off.

6.8

Turning the demister heating

elements on/off manually (only if

the parameter u1 and/or

parameter u11 is set at 1)

To turn the demister heating elements on, proceed as follows:

1.

Check that the device is turned on and no

procedures are in progress.

Defrosting manual activation