EVCO EVB1256N9 User Manual

Page 78

Advertising
background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.2 | Code 144BOX1E124

page 78 of 88

CSd

Compressor shut down alarm.

Solutions:

-

check the condenser temperature; see parameter C7

-

switch the device off and back on again: if when the device is switched back on, the temperature of the

condenser is still higher than that established in parameter C7, disconnect the power supply and clean the

condenser

Main consequences:

-

the compressor and the evaporator fan will be switched off

-

the alarm output will be activated (provided that parameter u1 and/or parameter u11 is set at 3)

-

the condenser fan will be on (only if parameter u1 and/or parameter u11 is set at 6)

dFd

Defrosting alarm switched off because maximum time has been reached

Solutions:

-

check the integrity of the evaporator temperature probe; see parametersd2, d3 and d11

-

press a key to restore normal display

Main consequences:

-

the device will continue to operate normally

Pd

Pump down alarm (from digital input) finished for maximum duration

Solutions:

-

check the integrity of the sensor switching off the compressor

Main consequences:

-

the device will continue to operate normally

When the cause of the alarm disappears, the device restores normal operation, except for the following alarms:

-

the power supply interruption alarm (code “PF”) which requires the pressing of a key

-

maximum pressure switch alarm (code “iSd”) which requires the switching off of the device or the temporary suspension of

the power supply

-

compressor blocked by condenser temperature alarm (code “CSd”) which requires the switching off of the device or the

temporary suspension of the power supply

-

defrosting alarm switched off because maximum time has been reached (code “dFd”) which requires the pressing of a key.