EVCO EVB1256N9 User Manual

Page 32

Advertising
background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.2 | Code 144BOX1E124

page 32 of 88

dur

the display is about to show the alarm duration

h01

the alarm lasted for 1 hour (continue...)

n15

the alarm lasted 1 hour and 15 min

code

the alarm selected

the displays each piece of information for 1 s.

To exit the information sequence:

7.

Press and release the “ON/STAND-BY”: the display

will show the alarm selected.

To exit the procedure:

8.

Exit the information sequence.

9.

Press and release the “UP” or “DOWN” key until

the display shows the magnitude established with

parameter P5 or do not operate for 60 sec.

Alternatively:

10.

Press and release the “ON/STAND-BY” key.

10.3

Cancelling the HACCP alarm list

To cancel the HACCP alarm list proceed as follows:

1.

Make sure that the keyboard is not locked and that

no procedure is in progress.

2.

Hold the key “DOWN” for 1 s: the display will show

the first label available.

3.

Press and release the "UP" or "DOWN" key to

select “rLS”.

4.

Press and release the “SET” key.

5.

Press and release the “UP” or “DOWN” key within

15 s to set “149”.

6.

Press and release the “SET” or do not operate for

15 sec: the display will show a flashing “- - -” for 4

sec and the “HACCP” LED switches off, after which

the device will exit the procedure.

If the device does not have any alarms stored, the label “rLS

will not be displayed.

Access the procedure to cancel information on the HACCP alarms

Cancelling information on the HACCP alarms

Advertising