FingerTec R2c Installation Guide User Manual

Installation guide, Step 2 mounting of terminals on a wall, R2 & r2c

Advertising
background image

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

Back Plate

4 feet / 1.2 meter

(recommended)

1

2

3

4

5

6

7

8
0

9

ESC

OK

MENU

USB
Port

R2

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

GND

+12V

DC12V 3A

Power

Supply

BEEP

GLED

RLED

INWD0

INWD1

GND

+12V

Wiegand

IN

Power

OUT

3rd party

controller with

26-bits wiegand

output

RJ45-1

RJ45-2

RJ45-3

RJ45-6

WD0

WD1

GND

RXD

TXD

GND

485+

485-

TCP/IP

Wiegand

OUT

RS232

RS485

3rd party controller

with 26-bits wiegand

input

RS232

cable

TCP/IP

RX+

RX-

1. RS485 Single Connection

RS232/RS485

Data Converter

485B

485A

RX+

RX-

RS232/RS485

Data

Converter

2. RS485 Network Connection

485B

485A

485B

485A

Door Lock connector.
Refer to Appendix I

Step 1

Determine the Location and Positioning

of the Installation

Avoid installing the terminals in locations that has contact with
a strong light source (e.g direct sunlight, spotlight, fluorescent
light, etc)

Avoid installing the terminals in locations with high moisture or

condensation levels in the air

The recommended installation height of the terminal from the
ground is 1.2 meter.

Step 2

Mounting of Terminals on A Wall

After determining the height of the terminal from the ground
level and have made the relevant marks on the wall, drill the
screws into the wall to hang the back plate.

Refer to Appendix II for dimensions and measurements of instal-

lation.

Installation Guide

w w w . f i n g e r t e c . c o m

R2 & R2c

Fingerprint Door Access &

Time Attendance System

Step 3

Wiring for Power Supply

The power input ports for these models are located at the rear of
the terminals. There is no adapter plug supplied with the models,
instead you need to source for power cable (red and black cables)
to connect the power from the terminal to the AdapTec.

1

2

3

4

5

6

7

8
0

9

ESC

OK

MENU

R2c

w

Advertising